TGA100 Rev0106
32
Figure 11. Caterpillar TGA105/205 Wiring
(Sheet 3 of 3)
Some Older Engine Interface
Engines with 40-pin OEM connector.
If the remote throttle option is not available in the ECM program, a relay needs to
be installed to provide this capability. Wire the relay into the cab foot throttle harness,
connect the InControl Engine Control cable, and supply 12 volts to the coil form the
pump interlock circuit. Refer to the wire diagram below.
J1587 Datalink
Negative (–)
Note: Supply 12 VDC
when the pump interlock
circuit is engaged.
J1587 Datalink
Positive (+)
White
Wire
Black
Wire
C993-BR
C985-BU
C986-BR
8 VDC
Sensor Common
Ground
Throttle Position Input
PWM
35
37
29
ECM
1
7
Black Wire
Red Wire
40-Pin
Vehicle
Harness
Connector
NC
NO
NC
NO
C
C
A
B
C
P50
J50
Cab Foot
Throttle
Relay
A
C
B
Red
Wire
Black
Wire
White
Wire
IN4006
Diode
12-Pin
Connector
(Refer to
Figure 4)
8-Pin
Connector
(Refer to
Figure 5)
J1587 Datalink
J1587 Datalink