Warning!
The 0 V (negative) output of the 24 V DC supply to the bar must be earthed.
If this is not done, the bar and the power supply will be damaged and all
warranties will be voided.
Electrical connections to the bar are made via the M12 5-pole male connector on
the endcap of the bar.
If using the Fraser Anti-Static external Power Supply Unit (Part No. NEOS-PSU),
connect the M12 cable from the Power Supply Unit to the bar and ensure that the
supplementary ground wire is connected to the installation protective earth before
connecting mains power.
If using a separate 24 V Power Supply and Cable (e.g. as part of a machine control
cabinet installation), follow the instructions in Section 5.2 for connecting the bar.
5.
Electrical Connections