Fraser IONFIX COMPACT Скачать руководство пользователя страница 8

8

IONFIX_PRO GEN_Quick Guide_Iss.1

Technical Specifications

Electrical Characteristics

Input rating:

 

 

 

90 – 250 V AC, 47 – 63 Hz, 3 A max.

Input connector: 

 

 

IEC 60320 C14 inlet.

Output rating, 30 kV variants: 

 

0-30 kV DC, 5 mA max.

Output rating, 60 kV variants: 

 

0-60 kV DC, 2.5 mA max.

Output connector type:

 

 

4 x Fraser 30/60 kV tubular spring-contact HV connector.

Remote interface connector:

   

25-pin subminiature D-type, female.

 

 

 

 

Mating plug Amphenol L717DB25P or equivalent.

Environmental Conditions

Ambient temperature:

 

 

0 – 50 °C

Relative humidity: 

 

 

Maximum 70%, non-condensing.

Ingress protection: 

  IP20.

Mechanical

Dimensions (D x W x H):

 

 

337 mm x 268 mm x 104 mm

Weight:

 

   8 

kg

Содержание IONFIX COMPACT

Страница 1: ...IONFIX PRO STATIC GENERATOR WITH REMOTE MONITORING AND CONTROL INTERFACE QUICK START GUIDE...

Страница 2: ......

Страница 3: ...medical attention If the generator is to be operated by ordinary persons it must be installed in such a manner that the high voltage output connectors are not accessible in normal operation for examp...

Страница 4: ...n energised Refer to the full manual for detailed installation instructions 1 Ensure that the generator is correctly earthed as described above 2 Securely mount the generator in a visible accessible a...

Страница 5: ...output is enabled Remote indicator Illuminates when any of the remote control functions are enabled Current Limited indicator Illuminates when the output current reaches the limit value RUN STOP Butt...

Страница 6: ...continuous charging source When delivered the output voltage setpoint will be set to zero and the current limit set to its maximum value Enable the HV output press RUN STOP and increase the output vo...

Страница 7: ...arameter value OK Move down to a lower menu level save parameter setting Pressing any of the setpoint adjustment buttons Voltage Current whilst using the menu will exit the menu system Remote Interfac...

Страница 8: ...t rating 60 kV variants 0 60 kV DC 2 5 mA max Output connector type 4 x Fraser 30 60 kV tubular spring contact HV connector Remote interface connector 25 pin subminiature D type female Mating plug Amp...

Страница 9: ...signal provided Provide remote on off signal Current limit set too low Increase current limit using Current buttons All LEDs flashing OVERLOAD shown on display Arcing or short circuit on HV output due...

Страница 10: ......

Страница 11: ......

Страница 12: ...evon GB EX16 9DN T 44 0 1398 331114 F 44 0 1398 331411 E sales fraser antistatic co uk W www fraser antistatic com For more information about static and to view the full range of our products please v...