Generator configuration menu

The generator configuration menu has four sections:

1.  Remote Mode

 – allows the generator remote interface to be enabled and configured.

2.  Advanced Settings

 – allows various aspects of generator operation to be adjusted.

3.  System Information

 – provides diagnostic information about the generator.

   

      4.     Fault Count

 - provides diagnostic information about the generator.

See the full manual for details of the configuration menu and settings/parameters.

To access the menu the following keys are used:

•  Right (

):

 Enter menu system, move down to a lower level, access parameter to adjust.

•  Left (

)

: Move up to a higher menu level, exit menu system.

•  Up (

)

: Move up a list of menu items, increase parameter value.

•  Down (

):

 Move down a list of menu items, decrease parameter value.

• OK:

 Move down to a lower menu level, save parameter setting.

Pressing any of the setpoint adjustment buttons (V/-, C/-) whilst using the menu will exit 
the menu system.

Remote Interface

The generator is equipped with a remote control and monitoring interface, provided on a 25-way D-type 
socket at the rear of the generator. The functions and connections are as follows:

Pin No.

Function

Pin No.

Function

1

Remote on/off input +ve

14

Remote on/off input -ve

2

Remote current setpoint input

15

GND (0 V)

3

Remote voltage setpoint input

16

GND (0 V)

4

Remote voltage monitor output

17

GND (0 V)

5

Remote current monitor ouput

18

Reserved, do not connect

6

Reserved, do not connect

19

GND (0 V)

7

+12 V reference output

20

GND (0 V)

8

Reserved, do not connect

21

Reserved, do not connect

9

Arc/Limit open collector

22

Arc/Limit open emitter

10

Operating open collector

23

Operating open emitter

11

Reserved, do not connect

24

GND (0 V)

12

Not connected

25

Reserved, do not connect

13

Not connected

Содержание IONFIX COMPACT

Страница 1: ...IONFIX PRO STATIC GENERATOR WITH REMOTE MONITORING AND CONTROL INTERFACE QUICK START GUIDE...

Страница 2: ......

Страница 3: ...medical attention If the generator is to be operated by ordinary persons it must be installed in such a manner that the high voltage output connectors are not accessible in normal operation for examp...

Страница 4: ...n energised Refer to the full manual for detailed installation instructions 1 Ensure that the generator is correctly earthed as described above 2 Securely mount the generator in a visible accessible a...

Страница 5: ...output is enabled Remote indicator Illuminates when any of the remote control functions are enabled Current Limited indicator Illuminates when the output current reaches the limit value RUN STOP Butt...

Страница 6: ...continuous charging source When delivered the output voltage setpoint will be set to zero and the current limit set to its maximum value Enable the HV output press RUN STOP and increase the output vo...

Страница 7: ...arameter value OK Move down to a lower menu level save parameter setting Pressing any of the setpoint adjustment buttons Voltage Current whilst using the menu will exit the menu system Remote Interfac...

Страница 8: ...t rating 60 kV variants 0 60 kV DC 2 5 mA max Output connector type 4 x Fraser 30 60 kV tubular spring contact HV connector Remote interface connector 25 pin subminiature D type female Mating plug Amp...

Страница 9: ...signal provided Provide remote on off signal Current limit set too low Increase current limit using Current buttons All LEDs flashing OVERLOAD shown on display Arcing or short circuit on HV output due...