P
roduct
S
PecificationS
8
www.franklinhvacsystems.com
SS-FGMBR
The manufacturing entity reserves the right to discontinue or change the specifications
or design at any time without notice and without incurring any obligations.
w
iRing
d
iagRaM
– 5 e
leMent
H
eateR
k
it
M9
M10
TL
FL
HTR1
HTR2
HTR3
HTR4
M6
M5
L2
L2 L1
RD
BL
BK
YL
RD
BK
BK
RD
M1
M3
YL
BL
BK RD
M2
R1
M4
PU
9
8
WH
M8
7
6
BR
5
M7
R2
BL
RD
BL
4
3
2
BL
YL
BK
1
PC
RD
BK
HTR5
L1
L2
L1
BL
R3
PU
PU
L2
L1
CB4
CB3
CB1
CB2
WH
PU
TL
FL
TL
FL
TL
FL
TL
FL
COLOR CODE
BK = BLACK
BL = BLUE
BR = BROWN
PK = PINK
RD = RED
WH = WHITE
YL = YELLOW
WIRING CODE:
HIGH VOLTAGE
LOW
VOLTAGE
COMPONENT CODE
PC = 9 PIN CONNECTOR
HTR = HEATER ELEMENT
TL = THERMAL LMT
RS = RELAY/SEQUENCER
TB = TERMINAL BLOCK
CB = CIRCUIT BREAKER
CC = CONTACTOR
FL = FUSE LINK
TR = TRANSFORMER
SR = STRAIN RELIEF
EM = EVAPORATOR MOTOR
EBTDR = ELEC. BLOWER TIME DELAY
RC = RUN CAPACITOR
GR = GREEN
OR = ORANGE
PU = PURPLE
0140M00274-A
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR
EQUAL THE MINIMUM BLOWER
SPEED (MBS) SPECIFIED FOR THE AIRHANDLER /
HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE.
AFTER INSTALLING
OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW.
NO MARK INDICATES NO HEAT KIT INSTALLED.
FIVE (5) ELEMENT ROWS
NOTE:-
THIS LABEL MUST BE ATTACHED ON THE
AIRHANDLER IN A PROMINENT LOCATION
BK RD
BK
RD
w
iRing
d
iagRaM
– 3 P
Hase
H
eateR
k
it
RC
BR
BR
EM
3
5
2
1
4
RD
TR
WH
BR
BK
L2
L1
RD
RD
BL
BK
PU
BL
PU
RELAY/SEQUENCER
THERMAL LIMIT
TRANSFORMER
RUN CAPACITOR
ELEC. BLOWER TIME DELAY RELAY
EVAPORATOR MOTOR
HEAT ELEMENT
HTR
EBTDR
EM
RS
TL
TR
RC
COMPONENT CODE
24 VOLT
TR
RC
EM
EBTDR
EBTDR
COM
NO
NC
208/240 VOLTS
0140M00273-A
WH
BK
GND
L3
T3
CC
L2
L1
BL
T2
T1
R
BL
RD
BR
M3
M4
PU
M2
PU
WH
M1
WH
WH
RS
BL
WH
PU
BL
RD
1
2
3
5
7
8
9
6
4
WH
PC
EBTDR
TERMINAL BLOCK
CONTACTOR
9-PIN CONNECTOR
PC
CC
TB
M2
RS
M1
M3
M4
L1
L2
LOW
HIGH
CC
HEATER CONTROL
AR POWER SUPPLY
1
2
3
4
5
6
7
8
9
PC
(CIRCUIT 1)
NC
SPEEDUP
GR
C
RD
XFMR-R
XFMR-C
M1
COM
K1
NO
K1
L1
RD
GR
PK
BL
PU
SR
STRAIN RELIEF
M1
YL YELLOW
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
COLOR CODE
(CIRCUIT 2)
HKR POWER SUPPLY
L1
L2
L3
FL
SR
FUSE LINK
W2 W1
W
BR
GR
BL
PK
GR
C
RD
T1
T2
T3
1
2
3
4
5
FL
HTR3
TL
FL
HTR2
TL
FL
HTR1
TL
TL
FL
HTR3
TL
FL
HTR2
TL
FL
HTR1
CB
CIRCUIT BREAKER
L1
L2
L3
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
WIRING CODE
HIGH VOLTAGE
LOW VOLTAGE
BK
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER
SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE.
AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW.
NO MARK INDICATES NO HEAT KIT INSTALLED.
NOTE:-
THIS LABEL MUST BE
ATTACHED ON THE
AIRHANDLER IN A PROMINENT
LOCATION
BK
RD
TB
L1
L2
CIRCUIT 1
1 PH 208-240V
CIRCUIT 2
3 PH. 208-240V