INSTALLATION AND SETUP
Installation Process
14
Standard Submersible Constant Pressure System
The above drawing illustrates how a typical submersible pump system should be arranged for a
constant pressure application.
1.
Pump and Franklin Electric Motor.
Refer to the Franklin Electric AIM Manual for pump, pipe,
and cable sizing information.
2.
Check Valve
3.
Pressure Relief Valve:
Pressure relief valve must be able to pass full pump flow at 100 PSI.
4.
Pressure Tank:
Refer to
“Minimum Pressure Tank and Supply Pipe Sizing” on page
5.
Pressure Gauge
6.
Pressure Transducer or Sensor:
Install in a vertical position.
7.
SubDrive/MonoDrive Connect VFD
8.
Power Supply from Circuit Breaker.
Single phase, 208/230 VAC +/- 10%.
9.
Power to Motor:
Single phase or Three-Phase (except MonoDrive).
A tank tee is recommended for mounting the tank, pressure transducer, pressure gauge, and pres-
sure relief valve. If a tank tee is not used, the pressure transducer or pressure sensor should be
within 6 feet (1.8 meters) of the pressure tank to minimize pressure fluctuations. There should be
no elbows between the tank and pressure transducer or pressure sensor.
Risk of bodily injury or property damage.
•
Pumps can develop very high pressure in some situations. Always install a pressure relief
valve able to pass full pump flow at 100 psi.
•
Install the pressure relief valve near the pressure tank and route to a drain capable of full sys-
tem flow.
Содержание MonoDrive
Страница 1: ......
Страница 56: ...SPECIFICATIONS Notes 56 Notes ...
Страница 57: ...SPECIFICATIONS Notes 57 Notes ...
Страница 58: ...SPECIFICATIONS Notes 58 Notes ...
Страница 61: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manuel d utilisation ...
Страница 120: ...SPÉCIFICATIONS Normes en vigueur 60 Remarques ...
Страница 123: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manual del propietario ...