background image

18

  The Company reserves the right at any time, and from time to time, to make changes in the design and/or 

improvements upon its product without thereby imposing any obligation upon itself to make corresponding 

changes or improvements in or upon its products already manufactured and/or previously sold. The Company 

further reserves the right to substitute parts or components of substantially equal quality in any warranty service 

required by operation of this Limited Warranty.

  This written Limited Warranty is the entire warranty authorized and offered by the Company. There are no 

warranties or representations beyond those expressed in this document.

  THIS WARRANTY AND REMEDY IS IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES INCLUDING 

WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR 

PURPOSE, WHICH ARE HEREBY SPECIFICALLY DISCLAIMED AND EXPRESSLY EXCLUDED.  CORRECTION 

OF NON-CONFORMITIES, IN THE MANNER AND FOR THE PERIOD OF TIME AS SET FORTH ABOVE, SHALL 

CONSTITUTE FULFILLMENT OF ALL LIABILITY OF THE COMPANY TO THE PURCHASER WHETHER BASED 

ON CONTRACT, NEGLIGENCE, OR OTHERWISE.

 

THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES SUCH 

AS, BUT NOT LIMITED TO:

  DAMAGE TO OR LOSS OF OTHER PROPERTY OR EQUIPMENT, LOSS OF USE OF EQUIPMENT, FACILITIES 

OR SERVICE, LOSS OF PROFIT OR SALES, COST OF PURCHASES OR REPLACEMENT GOODS, CLAIMS OF 

CUSTOMERS OF THE PURCHASER, FAILURE TO WARN AND/OR INSTRUCT, LOSS OF OTHER PRODUCTS, 

OR COSTS OF ENVIRONMENTAL REMEDIATION, OR DIMINUTION IN PROPERTY VALUE. THE REMEDIES 

OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE, AND THE LIABILITY OF THE COMPANY SHALL 

NOT, EXCEPT AS EXPRESSLY PROVIDED HEREIN, EXCEED THE PRICE OF THE PRODUCTS UPON WHICH 

SUCH LIABILITY IS BASED. DAMAGES AS SET FORTH IN THIS PARAGRAPH SHALL BE REASONABLY 

MITIGATED TO THE EXTENT POSSIBLE. THIS PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES 

RESULTING FROM CONDITIONS SET FORTH IN SECTION III ABOVE AND (1) DEFECTS IN PRODUCT 

PROTOTYPES OR REPLACEMENT PART PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION, 

CIRCULATED, AND SOLD BY THE COMPANY, AND/OR (2) DEFECTS THAT WERE NOT FOUND AT THE TIME 

OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS.

 

This Limited Warranty gives you specific legal rights. You may have other rights, which vary according to the 

applicable laws and regulations. Where any term of this warranty is prohibited by such laws, it shall be null and void, 

but the remainder of this warranty shall remain in full force and effect.

  DISCLAIMER: Any oral statements about the product made by the seller, the Company, the representatives or any 

other parties, do not constitute warranties, shall not be relied upon by the user, and are not part of the contract for 

sale. Seller’s and the Company’s only obligation, and buyer’s only remedy, shall be the replacement and/or repair by 

the Company of the product as described above. Before using, the user shall determine the suitability of the product 

for his intended use, and user assumes all risk and liability whatsoever in connection therewith.

Содержание Little Giant Pit+Plus 9JP2V2DA1

Страница 1: ...Pit Plus Installation Guide Patent Pending ...

Страница 2: ...r may they play with the equipment or in the immediate vicinity If the power cord is damaged it must only be replaced by qualified personnel Keep work area clean well lit and uncluttered Keep safety labels clean and in good condition Wear safety glasses while installing or performing maintenance on pump Do not run pump dry Fill pump with water before starting or pump will be damaged Make sure all ...

Страница 3: ...etting Started 2 Features 4 Start Up Procedure 5 Troubleshooting Guide 7 Replacement Parts 9 Pit Plus Jr with ECM 10 Pit Plus Jr with Floats 11 Pit Plus Sr with ECM 12 Pit Plus Sr with Floats 13 ECM 14 Maintenance 15 Warranty 17 ...

Страница 4: ...ional alarm External Control Module ECM 4 The optional ECM is an advanced control switch for a sewage basin Pump Access Cover 5 The pump access cover allows access to pump for removal and installation Removal of the access cover also allows the installer to monitor operation of the level control float switch and the optional alarm float switch during installation or service Discharge and Vent Pipe...

Страница 5: ... raised molded features on the bottom of the basin and reconnect discharge pipe to exit pipe with flexible coupling and band clamps Step 5 Examine level control float switch and optional alarm float if included Verify the float pole is secured to bottom of control cover and there are no obstructions that might interfere with the operation of the level control float switch or alarm float switch Not...

Страница 6: ...n be made Step 8 Connect the basin discharge pipe to drain pipe A check valve not included must be installed near basin to prevent backflow into basin For best performance of check valves when handling solids install in a horizontal position or at an angle not more than 45 degrees Step 9 Connect the Pit Plus vent pipe to vent pipe Step 10 Connect piggyback plug to a 115 V outlet Plug the pump powe...

Страница 7: ...outlet 4 Turn on electrical power 5 If pump operates the switch is in failure mode Pump will operate but water waste will not exit basin Blocked discharge pipe Remove blockage Blocked vent pipe Remove blockage Note Air admittance valves can create problems with sealed sewage basins They restrict the free passage of air in the vent pipe that is needed for efficient pumping Pump is air locked 1 Cons...

Страница 8: ...s pump capacity Larger pump required Defective switch Disconnect switch check with ohmmeter open infinitive resistance closed zero Loose connection in level control wiring Check control wiring Pump runs but does not discharge liquid Check valve installed backwards Check flow indicating arrow on check valve body to ensure it is installed properly Check valve stuck or unplugged Remove check valve an...

Страница 9: ...Premium Simplex Package Systems 9 Replacement Parts Replacement Parts Pit Plus Jr with ECM Replacement Parts Pit Plus Sr with ECM Replacement Parts Pit Plus Jr with Floats Replacement Parts Pit Plus Sr with Floats ...

Страница 10: ... 2 2V2D Models 2 2V3D and 3V2D Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 13 1117617 1 4 20 x 1 Bolt 16 14 1127502 1 4 Flat Washer 16 15 925033 Cord Grommet 1 Hole For Models without Alarm 1 925014 Cord Grommet 2 Hole For Models with Alarm 1 16 116710 Stainless Band Clamp for Alarm Float For Models with Alarm 1 17 113254 Cord Clamp For Models with Alarm 1 18 945015 Fernco 3 For...

Страница 11: ...D Models 1 113563 Discharge Pipe 3 2V3D and 3V3D Models 1 18 113565 2 x 6 Vent Discharge Pipe 2V2D Models 2 2V3D and 3D2V Models 1 113566 3 x 6 Vent Discharge Pipe 3V3D Models 2 2V3D and 3V2D Models 1 19 925033 Grommet 2 2V2D Models 2 2V3D and 3D2V Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 20 1117617 1 4 20 x 1 Bolt 17 21 1127502 1 4 Flat Washer 17 22 925014 Cord Grommet 2 Hol...

Страница 12: ... 2 2V2D Models 2 2V3D and 3V2D Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 13 1117617 1 4 20 x 1 Bolt 16 14 1127502 1 4 Flat Washer 16 15 925033 Cord Grommet 1 Hole For Models without Alarm 1 925014 Cord Grommet 2 Hole For Models with Alarm 1 16 116710 Stainless Band Clamp for Alarm Float For Models with Alarm 1 17 113254 Cord Clamp For Models with Alarm 1 18 945015 Fernco 3 For...

Страница 13: ...D Models 1 113563 Discharge Pipe 3 2V3D and 3V3D Models 1 18 113565 2 x 6 Vent Discharge Pipe 2V2D Models 2 2V3D and 3D2V Models 1 113566 3 x 6 Vent Discharge Pipe 3V3D Models 2 2V3D and 3V2D Models 1 19 925033 Grommet 2 2V2D Models 2 2V3D and 3D2V Models 1 925023 Grommet 3 3V3D Models 2 2V3D and 3V2D Models 1 20 1117617 1 4 20 x 1 Bolt 17 21 1127502 1 4 Flat Washer 17 22 925014 Cord Grommet 2 Hol...

Страница 14: ...s ECM REPLACEMENT PARTS ITEM NO PART NO DESCRIPTION QTY 1 113264 ECM Housing 1 2 113263 ECM Cover 1 3 902511 Screw 10 x 1 1 8 SST 4 4 950320 Switch 1 5 108125 Diaphragm 1 6 902404 Switch Holder Screw 1 7 108202 Switch Holder 1 8 951060 Wiring Harness 115 V 18 FT 1 ...

Страница 15: ...ng and remove pump Step 7 Remove discharge pipe from pump and install on replacement pump Step 8 Install replacement pump into basin Position pump so that the lower discharge pipe aligns with the basin discharge pipe Step 9 Position flexible adapter so that it is centered on the lower and upper discharge pipes and tighten band clamps Step 10 Feed power cord through the cord grommet opening and rei...

Страница 16: ...odule to basin and secure with six 6 bolts Step 9 Insert cords in cord grommet and install cord grommet into the switch module Caution Remove any cord slack that might potentially interfere with control float or optional alarm float operation Step 10 Connect switch and pump to power supply ECM External Control Module Removal and Installation Step 1 Disconnect pump and switch from power supply Step...

Страница 17: ...ion repair or replace defective parts Repaired or replaced parts will be returned freight prepaid by the Company 4 This warranty policy does not cover any labor or shipping charges The Company shall not be liable for any costs or charges attributable to any product testing maintenance installation repair or removal or for any tools supplies or equipment needed to install repair or remove any produ...

Страница 18: ...URE TO WARN AND OR INSTRUCT LOSS OF OTHER PRODUCTS OR COSTS OF ENVIRONMENTAL REMEDIATION OR DIMINUTION IN PROPERTY VALUE THE REMEDIES OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE LIABILITY OF THE COMPANY SHALL NOT EXCEPT AS EXPRESSLY PROVIDED HEREIN EXCEED THE PRICE OF THE PRODUCTS UPON WHICH SUCH LIABILITY IS BASED DAMAGES AS SET FORTH IN THIS PARAGRAPH SHALL BE REASONABLY MITIGATED TO...

Страница 19: ...19 NOTES ...

Страница 20: ...701 7894 Pour l aide technique entrez s il vous plaît en contact 800 701 7894 Para la ayuda técnica por favor póngase en contacto 800 701 7894 www littlegiant com lgnet fele com Franklin Electric Co Inc Oklahoma City OK 73157 2010 Phone 1 800 701 7894 Fax 1 405 228 1561 ...

Отзывы: