Inline Pressure Boosting System
15
Inline 400 Troubleshooting Guide
Condition
Indicator Lights
Possible Cause
Corrective Action
Unit will not turn
on- No GREEN
or RED LED
illuminated on
control cap
None
Circuit breaker tripped or turned off
Turn on the circuit breaker
None
Circuit breaker tripped or turned off
Consult a licensed electrician to
properly wire outlet
Unit runs briefly,
won't develop
pressure, then
turns off
Flashing Green (10s) then flashing RED
Insufficient water
Check water supply and valving
Flashing Green (10s) then flashing RED
Unit insufficiently primed
Refer to owner’s manual’s section on
proper priming technique
Flashing Green (10s) then flashing RED
Dry running
Check water supply and valving
Unit won't start
with water
demand
Solid Green
Inlet water pressure above 40PSI
Install a Pressure Reducing valve on
inlet to reduce inlet pressure
Unit continuously
cycles ON/OFF
(Rapid Cycle)
Flashing Green
Improper charge pressure in tank
Set the pressure in pressure tank to
2PSI lower than cut-in pressure
Flashing Green
Check valve between tank and unit
Place check valve after pressure tank
Unit won't turn on
Solid RED
Unit is turned OFF
Press the power button on the user
interface
Flashing RED
Overvoltage (input voltage higher than
+5%)
Check the supply voltage and correct
if possible
Flashing RED
Undervoltage (input voltage lower than
-5%)
Check the supply voltage and correct
if possible
Flashing RED
Overheating due to excessive water
temperature
Supply cold water to the pump
Flashing RED
Pump is in alarm condition
Reset pump by pressing power button
Unit runs
or cycles
continuously
Flashing Green
Leak/usage above 1/2gpm in system
plumbing
Repair the leaking plumbing
Flashing Green
Internal non-return valve is blocked/
damaged
Place a new non-return valve before unit
in INLET plumbing
Flashing Green
Internal flow piston is stuck open
Clean the flow piston (see page 14)
NOTE:
The motor in this unit contains thermal protection that responds to motor current and heat from the motor winding and ambient
temperature. When the combination of current and heat exceeds a predetermined point, the protector opens and interrupts the circuit.
When the winding termperature returns to a more normal level, the protector will automatically reset.
Содержание Inline 400
Страница 1: ...Inline Pressure Boosting System Owner s Manual ...
Страница 21: ...21 NOTES ...
Страница 22: ...22 NOTES ...
Страница 23: ...23 NOTES ...
Страница 25: ...Sistema de presurización Inline Manual del usuario ...
Страница 45: ...21 NOTAS ...
Страница 46: ...22 NOTAS ...
Страница 47: ...23 NOTAS ...
Страница 49: ...Système de surpression Inline Manual du propriétaire ...
Страница 69: ...21 REMARQUES ...
Страница 70: ...22 REMARQUES ...
Страница 71: ...23 REMARQUES ...