INSTALLATION INSTRUCTIONS
Fitted units
• This appliance is only intended to be fully fitted in a kitchen.
• This appliance is not designed to be used as a tabletop appliance or inside a cupboard.
• The fitted cabinet must not have a back wall behind the appliance.
• A gap of at least 100mm must be maintained between the wall and the base or back panel of the
unit above.
• The fitted cabinet must have a ventilation opening of 250cm
2
on the front. To achieve this, cut
back the base panel or fit a ventilation grille.
• Ventilation slots and intakes must not be covered.
• The safe operation of this appliance can only be guaranteed if it has been installed in accordance
with these installation instructions.
• The filter is liable for any damage resulting from incorrect installation.
• The units into which the appliance is fitted must be heat-resistant up 90
°
C
• Minimum installation heigh: 850mm
min 45
Cupboard feet
Ventilation grid
min 45
min 850