7
EN
Cleaning and maintenance
Replacing the cartridge
1.
Shut off the water supply to the faucet.
2.
Turn on the faucet briefly to relieve any
pressure inside the faucet.
3. Move the faucet handle to the “OFF”
position.
4. Remove the Plastic Cover (C) from
Handle (A).
5. Remove the Screw (B) using an allen
key.
6. Pull the Lever Base (A) from the faucet
body.
7. Unscrew the Cap (D).
8. Unscrew the Cartridge Lock Nut (E).
9. Lift Ceramic Disc Cartridge (F) from
the body and replace it with new
cartridge. Ensure the two lugs on
bottom of the cartridge sit properly in
the allocated holes at the base of the
body.
10. Re-assemble faucet in reverse order.
11. Test for leakage.
General maintenance
Clean aerator periodically for any buildup.
Do not use harsh detergents, solvents,
chemical agents, metallic sponges, etc.
that could harm the surface and damage
the finish. Clean only with a soft sponge
and soapy water.
Do not store chemicals or cleaning agents
in the immediate vicinity of the faucet and
connection hoses. Chemical vapors could
cause damage.
A
D
B C
E
F
2.5 mm
30mm
106 in-lbs