background image

5. Tap flow time alteration Instructions 

Important ! 

 
Before installing, flush the pipes in compliance with DIN 1988 
 

To Connect the water Supply. 

 

(1) 

Insert the Solenoid valve with the seals and check the direction of flow. 

 

(2) 

Guide the sensor module (g) through the cut-out in the front service panel. 

 
Note that the groove for the anti twist feature must face upwards. When the sensor is 
connected, the LED flashes at the Top. (Grub screw at the Top) 
Slide the disc onto the sensor module and use the nut to fasten the sensor module.  
 

(3) 

Use the adaptor cable (k) and extension (h) to connect the solenoid valve (i)     and the 

sensor module (g). 
 

(4) 

Connect the Connecting line (l) to the systems power supply. 

 

(5) 

Connect the system line to the power supply. 

 

(6) 

Connect the spout to the service panel. Using a flexible hose connect the end of the 

spout to the solenoid valve. (Again check the direction of flow) 
 
Secure service panel in place once Infra Red Sensor and Spout are fully connected. 

Warning! 

.

Installation, commissioning and maintenance are to be performed only by a 

qualified technician according to the instructions provided. 

.

Operate the product only with safety extra low voltage (SELV). Do not earth the 

components. 

.

The power supply must be set up outside of the wet area. 

.

 Secure the electric connection with an earth leakage circuit breaker (RCD). 

 
Failure to observe can mean risk of death or material damage, e.g. from electrical 
shock or fire. 

B1143

 – SANX400/405/03.03.2011                                                                                                                                                                                                                                                                                                                                                          3                     

8. Hotline 

Franke Sissons Ltd. 
Carrwood Rd 
Sheepbridge 
Chesterfield  S419QB 
T: +44-(0)1246-450255 
F: +44-(0)1246-451276 
E: [email protected] 

GBR Technical data 

Minimum flow pressure 1,0 

              Maximum operating pressure 10 bar 

Recommended flow pressure 3 bar               Flow duration 1 - 15 s adjustable 
 
The Premixed water supply should be a minimum 22mm Dia when entering the 
pedestal. It is recommended to connect a Thermostatic mixing valve before 
connecting to the units manifold framework. For satisfactory operation, a 
supply pressure of between 3 – 7 bar is required for entering the wash fountain 
pedestal. With recommended  flow rate of 36 l/min 
For pressures in excess of 7 bar g. a flow control or pressure reducing valve 
should  be fitted (Not supplied) 
 
 

 
To adjust the flow time of the Taps: 

 

For further repair/maintenance please refer to the taps service manual (Included) 

7. Securing Wash trough to the floor 

Please note that the base of the unit has 6 Dia 10.0mm holes that are positioned around 
its base section. These should be used to secure the unit to the floor. Use fixings which 
are appropriate to the type of flooring you are securing the unit to. (Note: Floor fixings 
are not supplied)   

 
 

Important !

 

Before installing, flush the pipes in 
compliance with DIN 1988 

 

To Connect Pre mixed water Supply. 

 
Insert a length of 22.0mm copper tube into the 
push fit connector at the base of the Manifold 
assembly . 
 
(Copper tube not supplied). 
(TMV3 Valve not supplied as standard). 
 
 

Отзывы: