The valve will require periodical servicing and cleaning, please
contact manufacturer for servicing.
Do not attempt to dismantle the valve if you are unfamiliar with
electronic solenoid valves.
- Check all connections (shown in Fig 2).
- Check fuse (Mains/PSU model only).
- Voltage too low. Check tap input voltage (PSU output voltage - 6v
DC).
- Voltage too low. Replace battery, CRP2 or DL223A Lithium Cell
only.
- Check / Clean all connectors (shown in Fig 3).
- Check for cable damage.
- For Mains/PSU models, disconnect PSU and reconnect after 30
seconds
- Check water is turned on.
- Check the solenoid valve is fitted correctly.
- Check valve operation.
- Check for dirt or debris in the solenoid valve.
- Water pressure is too high.
14.1 Tap operates in reverse
(Water runs when hand is moved away from sensing area and
stops when returned to sensing area). Reversed valve polarity
(contact manufacturer)
14.2 Tap operates intermittently
- Clean sensor lens (with nonabrasive materials only).
- Tap may be installed too close to an R.F. interference source).
- Tap may be installed too close to very bright lighting / highly
reflective surfaces.
- Water pressure too low for valve to operate reliably (minimum 0.5
BAR
14.3 Optional Parts
AT00 - 033 / 1m PSU cable extension
AT00 - 034 / 2m PSU cable extension
AT00 - 035 / 3m PSU cable extension
Warranty
The tap kit is guaranteed for 5 years from purchase against
defective material and assembly.
Support
For technical support please visit our technical pages on
our website at www.dartvalley.co.uk, contact us by email at
[email protected] or alternatively call us direct on
01803 529021.
13.1 General
In the absence of any other instruction or guidance on determining
the appropriate frequency of in-service testing, the following
procedure may be used:
a) 6-8 weeks after commissioning carry out the “In-Service Tests”
b) 12-15 weeks after commissioning carry out the “In Service Tests”
The results of the above tests may presence several possibilities:
a) If no significant changes (e.g. 1 K) in mixed water temperatures
are recorded between commissioning and 6 to 8 week
testing, or between commissioning and 12-15 week testing the
next in-service test can be deferred to 24 to 28 weeks after
commissioning.
b) If small changes (e.g. 1 to 2 K) in mixed water temperatures
are recorded in only one of these periods, necessitating
adjustment of the mixed water temperature, then the next
in-service test can be deferred to 24 to 28 weeks after
commissioning.
c) If small changes (e.g. 1 to 2 K) in mixed water temperatures are
recorded in both of these periods, necessitating adjustment
of the mixed water temperature, then the next in-service test
should be carried out at 18 to 21 weeks after commissioning.
d) If significant changes (e.g. > 2 K) in mixed water temperatures
are recorded in either of these periods, necessitating service
work, then the next in-service test should be carried out at 18
to 21 weeks after commissioning.
The general principle to be observed after the first 2 or 3 in-service
tests is that the intervals of future tests must be set to those which
previous tests have shown can be achieved, with no more than a
small change in mixed water temperature.
Fault Finding
13.2 Tap will not operate at all
- Check water is turned on.
- Check hot and cold feed connected correctly
- Check filters for debris
General Cleaning
Step 13 :
Frequency of In-Service Tests
AquariTherm Tap (Auto)
Installation, Maintenance & Operating Instructions
Dart Valley Systems
|
Kemmings Close
|
Long Road
|
Paignton
|
Devon
|
TQ4 7TW | UK
T +44 (0)1803 529 021
|
F +44(0)1803 559 016
|
www.dartvalley.co.uk
|
IMPORTANT:
Do not use abrasive materials or cleaners.
Only use soap and water or nonabrasive cleaners.
Step 14 :
Solenoid Valve Servicing
Step 2 :
Kit Contents
Step 1 :
Safety First
These instructions relate to the installation of the
AT04-002
AquariTherm Tap (Automatic)
only. Any external or ‘add-on’ parts
will be supplied with separate instructions.
Appropriate personal protective equipment must be worn when
installing, calibrating and commissioning this product.
It is recommended that any plumbing is carried out by a qualified
plumber. The electrical part of the installation must be carried out
by a qualified electrician in accordance with the latest electrical
regulations.
This is a sophisticated product which must be installed correctly to
perform correctly.
If the appliance is used by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, they must be given adequate
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with
the product.
A typical kit will include the following parts*:
Instruction Manual (x1)
IMPORTANT:
Please read these instructions carefully
and follow each stage in order!
*Not to scale
AC17-052 (x2)
AT00-037
AC17-006
AT00-029
AT07-082
PP0
0-
79
7 2
20
12
1
PP0
0-
79
7 2
20
12
1
AT00 - 122
MT04-006
PP00-360
PP00-359
AC02-017
AT04-002
AquariTherm Tap - Automatic
Seperate Sensor
c/w Standard Mains Kit