10. Setting the Signal Range
The signal range can be adjusted with a free program available from Franke.
11. Setting Hygiene Flushing
Hygiene flushing can be adjusted with a free program available from Franke.
12. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the fitting must be maintained and serviced at regular
intervals.
Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
13. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Fault
Cause
Remedy
Water does not flow
– Voltage supply interrupted
➯
Restore it
– Water supply interrupted
➯
Restore it
– Sensor module faulty
➯
Replace it
– Solenoid valve faulty
➯
Replace it
Water flows conti-
nuously
– Solenoid valve dirty
➯
Clean it
– Solenoid valve faulty
➯
Replace it
Water flow too weak
– Supply pressure too low
➯
Check it
– Water inflow not fully opened
➯
Open it