background image

EN

Boiler

191

407

276

96

∅35

96

181

29

ø

 

25

63,5

73

25º

200

330

304

96

∅35

96

180

63,5

73

25º

ø25

158

171

117

190

234,5

334,5

59

59

80

78

52

MAX

34min

80

59

59

362,5

78

52

MAX

34min

239,5

15

189

171

110

203

218

300

452

299

145

522

200

188

406

158

 

5 litre boiler

191

407

276

96

∅35

96

181

29

ø

 

25

63,5

73

25º

200

330

304

96

∅35

96

180

63,5

73

25º

ø25

158

171

117

190

234,5

334,5

59

59

80

78

52

MAX

34min

80

59

59

362,5

78

52

MAX

34min

239,5

15

189

171

110

203

218

300

452

299

145

522

200

188

406

158

 

10 litre boiler

Boiler

5 litre

10 litre

Dimensions [H x W x D]

145 x 522 x 200 mm

452 x 300 x 285 mm

Contents

4.7 l

10 l

Voltage

230 VAC

230 VAC

Power

1500 W

2200 W

Load

7.0 A

10 A

Energy consumption at standstill

25 W

28 W

IP classification

IP 24D

IP 24D

Storage temperature

115°C

108°C

Delivered water temperature

60° (±5)* and 100°C

60

°

 (±5)* and 100°C

Heating time [ΔT 100 K]

23 min

35 min.

Operating pressure (max.)

600 kPa / 87 psi / 6 bar

600 kPa / 87 psi / 6 bar

Suitable for hot-fill **

No

No

** The system must always be connected to a cold water supply.

M-Box

191

407

276

96

∅35

96

181

29

ø

 

25

63,5

73

25º

200

330

304

96

∅35

96

180

63,5

73

25º

ø25

158

171

117

190

234,5

334,5

59

59

80

78

52

MAX

34min

80

59

59

362,5

78

52

MAX

34min

239,5

15

189

171

110

203

218

300

452

299

145

522

200

188

406

158

M-box

Temperature of mixed water

55°C

Maximum water pressure

400 kPa

/

58 psi

/

4 bar

Filter system

Franke Pro M filter

Filter cartridge dimensions [h x w]

245 x 95 mm

Ambient temperature

4 - 30°C

Please note that some parts may not be available in your country.

Содержание Minerva 3-in-1

Страница 1: ...3 IN 1 INSTANT BOILING WATER SYSTEM EN 3 in 1 Instant boiling water system Installation and user manual...

Страница 2: ...EN 2 3x A B F H J I C G D E 1 2 6 5 4 3...

Страница 3: ...EN H I J J J 1 2 3 4 10 mm 3x 10 mm 3x RVS min 30 mm min 40 mm 35 mm Chroom min 30 mm min 60 mm 35 mm min 30mm min 30mm min 40mm min 60mm RVS Chrome 35mm 35mm B C F F D G G E E...

Страница 4: ...EN 10cm 2 cm 10cm 2cm 10cm 2 cm 10cm 2cm 1 2 6 5 4 3 M M M L K...

Страница 5: ...EN M M M M 6cm 1 2 4 5 6 3 4x 2cm L K K M M M H...

Страница 6: ...EN D E Z E Z IJ D E B O V E N T H IS S ID E U P D IE S E S E IT E N A C H O B E N C E C T V E R S L E H A U T TYPE SERIENUMMER 1 2 6 5 4 3 N O P N O...

Страница 7: ...TY PE SERIEN UMMER TYPE SERIAL NUMBER TY PE SERIEN UMMER TY PE SERIEN UMMER TYPE SERIAL NUMBER TY PE SERIEN UMMER TY PE SERIEN UMMER TYPE SERIAL NUMBER TY PE SERIEN UMMER TY PE SERIEN UMMER TYPE SERI...

Страница 8: ...T E N A C H O B E N C E C T V E R S L E H A U T DEZE ZIJDE BOVEN THIS SIDE UP DIESE SEITE NACH OBEN CE C T VERS LE HAUT VUL EERST DE BOILER MET WATER ZUERST DEN SPEIGER MIT WASSER F LLEN FIRST FILL TH...

Страница 9: ...EN O 1 2 N N N O O O...

Страница 10: ...EN I D E Z E Z IJ D E B O V E N TH IS S ID E U P D IE S E S E IT E N A C H O B E N C E C T V E R S L E H A U T OBEN E HAUT 1 2 Option 1 1 2 6 5 4 3 R Q Q Q Q I J H...

Страница 11: ...EN H I DE ZE ZI JD E BO VE N TH IS SI DE UP DI ES E SE IT E NA CH OB EN CE C T VE RS LE HA UT Option 2 3 I I J J H H...

Страница 12: ...EN DEZ E ZIJD E BOV EN THI S SID E UP DIE SE SEI TE NAC H OBE N CE C T VER S LE HAU T R 1 2 H H J J I I R R...

Страница 13: ...EN 12cm 1 1 2 6 5 4 3 T V U S...

Страница 14: ...EN 3 2 5 6 4 T V U U S S...

Страница 15: ...EN 1 2 3 4 120 0305 558 W W 1 2 6 5 4 3 W...

Страница 16: ...EN 5...

Страница 17: ...r 22 M Box 22 Installation instructions for push fitting 23 Icon legend 23 Installation 24 General starting points for installation 24 Installation video 24 Installation steps 24 Switching on for the...

Страница 18: ...EN Troubleshooting 29 Maintenance 31 General maintenance 31 Replacing filter cartridge 31 Descaling tap sieve 31 M Box 31 Disposal 32 Declaration of Conformity 32...

Страница 19: ...persons with reduced physical sensory or mental capacities or who lack the necessary experience or knowledge without supervision Z Z Prevent children from playing with the product and or system Z Z T...

Страница 20: ...water filter is mandatory to protect the product against lime scale deposits Z Z After storage at a temperature of 0 C the filter must first be stored for 24 hours at room temperature before it is in...

Страница 21: ...e water supply pressure and the type of tap 3 in 1 tap 330 304 158 171 117 190 234 5 334 5 59 59 80 78 52 MAX 34min 80 59 59 362 5 78 52 MAX 34min 239 5 15 189 171 110 158 Irena 3 in 1 158 171 117 80...

Страница 22: ...Delivered water temperature 60 5 and 100 C 60 5 and 100 C Heating time T 100 K 23 min 35 min Operating pressure max 600 kPa 87 psi 6 bar 600 kPa 87 psi 6 bar Suitable for hot fill No No The system mus...

Страница 23: ...g X X Push in the ring on the push fitting fig 1C X X Pull the hose out of the push fitting fig 1D 2C 2D Icon legend Product information Scope of Delivery Montage Tooling Equipment Do not use tools Me...

Страница 24: ...Z Mark the existing cold and hot water connection Z Z Do not connect the M Box to a hot water pipe Z Z There must be two wall plug sockets available for connection Installation video https youtu be 4K...

Страница 25: ...he water is cold X X Repeat the process three times to flush the complete system 10 litre boiler X X Operate the mixer tap and flush with warm water for 1 minute fig 3A X X Insert the plug into the wa...

Страница 26: ...1 cup of water to run out before filling the pot In this way the air bubbles in the water disappear so that no foam forms on the surface of the tea 5 litre boiler status indicator LED LED colour norma...

Страница 27: ...mode should be cancelled when the boiler is switched off ECO mode then has to be set again Note Before commissioning the boiler see Flushing Switching off the boiler 5 litre boiler X X Press the ON O...

Страница 28: ...laced Contact Franke or your installation company 9 9 Switch the boiler OFF 9 9 Remove the plug of the boiler from the wall plug socket 9 9 Remove the ON OFF knob by pulling it forwards fig 5A 9 9 Loo...

Страница 29: ...osed Open the stop valve Filter not installed in M Box Install filter in the M Box Tap supplies no boiling water Cause Remedy Hose s kinked Inspect the hose s and straighten the kinked hose s The M Bo...

Страница 30: ...a short circuit in the electric wiring or the heater element of the boiler Remove the plug of the boiler from the wall plug socket Contact Franke The boiler causes a short circuit No expansion water f...

Страница 31: ...ved servicing company or by Franke Service Replacing filter cartridge Filter 120 0305 558 lifespan Water hardness DH Months 10 DH 12 10 18 DH 9 18 DH 6 Z Z The filter cartridge must be changed at regu...

Страница 32: ...its working life the product must not be disposed of as household waste Consequently when the appliance has reached the end of its working life the user must take it to a suitable recycling centre for...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...hstan Ltd 040918 Almaty City Phone 7 727 297 3812 Morocco Franke Kitchen System SARL 21 000 Casablanca Phone 212 522 674 200 Norway Franke Kitchen Systems Norway 8520 Lystrup Denmark Phone 47 35 566 4...

Отзывы: