Franke MINERVA 119.0179.533 Скачать руководство пользователя страница 3

4

    Connect the waste T-piece (6) to the Inlet Pressure Relief Valve and 

Tundish (4) using the flexible plastic hose (7). The Tundish has a water 
trap in order to prevent odours from escaping from the waste pipe.

3

  Turn the stop valve (the small knob) on the Inlet Pressure Relief 

Valve to ‘OFF’ the turn on the mains water supply and check the 
assembly for leaks, and rectify as necessary. Once this check 
has been carried out, turn off the mains water supply again. The 
expansion discharge of the Inlet Pressure Relief Valve and the 
tundish must always point downwards and remain unobstructed.

1

  Install the 15mm stop valve included in the Water Filter 

Assembly (10). Determine the position to fit the 15mm 
Compression Tee (3) in the mains water pipework. Determine 
where the waste Tee piece (6) will be connected to the sink 
plastic waste pipe. 

Important note:

 There must be a minimum 

distance of 500mm between the bottom of the tundish and the 
inlet of the waste connector. If a waste disposal unit is installed, 
the waste water from the tundish must be piped to discharge 
directly into the soil stack, rather than the sink waste. 

  Install the 15mm compression Tee (3) 

and the waste saddle connection (6).

2

  Install the Filter Housing (10) to the 15mm compression Tee 

(3) Connect the Inlet Pressure Relief Valve (4) to the outlet of 
the filter. (Note there is an arrow in the top of the filter head 
indicating the direction of flow). Secure the filter unit securely 
using the bracket and screws provided. 

Important note:

 If the 

bracket is not employed the weight of the filter unit when full 
of water, will put undue strain on the pipework. The distance 
between the Pressure Relief Valve inlet and the boiling water 
heater must never exceed 1.5 metres. 

Cold 

mains 

water 

feed to 

supply 

tap and 

filter

Filtered 

water to 

heater 

tank only

4

4

3

6

10

Отзывы: