USE AND CARE
The Medi-flo sink is made from Miranit; a mineral composite with a premium gel coat. Avoid the use of strong
acids, paint removing compounds and abrasives.
12
12
SPARE PARTS
EN
(continued)
Solenoid & Control
Board Assembly
#AT00-181
Programmable
Control Board
#AT00-190
Solenoid Valve
#AC17-104
Mixing Valve
#MEDI-MIX
1
1
22
33
44
13
13
OZONE GENERATOR TECHNICAL INFORMATION
The electrolytic generator within Medi-flo not only generates a variety of oxidants which all work together to help destroy
harmful bacteria and viruses. The amount of mixed oxidants produced by the system is a function of the water conductivity
(total dissolved salts - TDS) and water composition such as hardness, alkalinity, PH, iron, manganese, etc.) and the flow rate
(or length of time the generator is running with or without water flow during the use or during trap purge disinfection cycles).
For optimum performance we recommend installation in areas with conductivity between 75-350TDS. If below 75TDS, the
ozone generator will still function down to as low as TDS of 50; however oxidant output may be reduced to under 0.5ppm
(measured by chemical reagent DPD tests). TDS can be measured using a small TDS reader, your local water or pool supply
store or by sending in a sample of 250ml minimum to our customer service. Tests such as ORP and Indigo may not give valid
readings due to hydrogen interference, temperature, water composition and PH. Subtract the reading obtained from straight
tap water to remove any reading from chlorine.
The default operation of the electrolytic generator is to run a charge cycle after every use. Target canister charge is 2.0ppm
of mixed oxidants. During this charge cycle, you will see the LED pulse in intensity (this can be adjusted or turned off with
the handheld programmer AC01-005). Typical output is approximately as follows:
@ 50 TDS =45min
@150 TDS =17min
@200 TDS =12 min
@250 TDS =7 min
@300 TDS =4 min
@350 TDS =3 min.
During a hand wash cycle, when the initial signal is received to wash hands, the user typically wets their hands and then
commences lathering. While they pull away their hands to lather, the water flow will stop but we keep the oxidant generator
running for 20 seconds to build up concentration in the chamber to be available for the rinse cycle. Alternatively, after
20 seconds of last use the water flow will automatically come on for an additional 3 seconds. The intention is that 20
seconds after last use the sink will dispense a small amount of water for a post rinse clean of the sink and trap to remove
any remaining soap residue. Water softeners will increase TDS and are recommended if your conductivity is low; however,
reverse osmosis or de-ionized water are not compatible with Medi-flo.