Franke filterflow Zurich filter system Скачать руководство пользователя страница 5

5

note.

 Depending on the nature of the cabinet it may be necessary to position  

a batten behind the panel to make a secure fixing. Remember the weight of the housing will 
increase when filled with water.

install the filter cartridge and assemble the filter housing

Unpack the new filter cartridge (L) and screw it into the housing head. Hand tighten the 
cartridge sufficient to make a watertight  seal.  

important.

 Do not overtighten the cartridge. Over tightening  may shear off the threaded 

section of the cartridge.

connect the filter housing to the filter tap 

Take the grey 3/8” push-fit connector (A) fitted to the free end of the blue plastic tube (B). 
Locate the 3/8” diameter stem attached to the base of your FrankeFlow filter tap. Wet the 
stem with a little water. Engage the push fit connector on to the end of the stem and push it 
fully home.  

important note—making the push-fit connections.

 Make  sure that the connector is 

pushed fully home on the 3/8” stem. Initial resistance will be felt as the stem engages the 
internal ‘O’ seal. It is essential to continue to push the stem fully home to the final stop to 
make a water tight seal. The stem should enter 10mm (3/8”) when fully engaged. Failure to 
fully engage the connector may result in a water leak or failure of the joint.    

turn the water on

Check to make sure all the connections are secure. Close the stop valve and turn the lever  
of your filter tap to the ‘ON’ position. Turn on the mains water supply and turn on the filter 
system stop valve. Check that the filtered water is running from the tap spout. Allow the water 
to run for a minimum of 5 minutes to flush the system before drinking the filtered water. 

important.

 for optimum removal performance adjust the stop valve to set the filtered water 

flow to fill a one litre jug in approximately 30 seconds.   

check the installation for leaks

Turn off the filter tap and carefully check the whole system for leaks; particularly at the 
connections to the stop valve, housing and tap. Turn on the filter tap and allow the filtered 
water to run for approximately 10 minutes to clear any manufacturing or installation residues. 
Your Franke FilterFlow water filter is now ready to use (as a precaution we recommend 
checking for leaks again before retiring for the night).

connect the filter housing to the stop valve

Select the stainless steel braided inlet hose (G). Connect the end with the 
1/2”BSP female nut to the male thread of the stop valve (H). Tighten the 
nut with a suitable spanner sufficient to make a watertight seal. 

important.

 Do not be tempted to over tighten the nut as it will distort the 

washer and cause the joint to leak.

Содержание filterflow Zurich filter system

Страница 1: ...franke filTerflow Zurich filTer sysTem installation guide technical information please retain for future reference...

Страница 2: ...rts are used to service your Franke FilterFlow These can be obtained on line at www FrankeFilterFlow co uk or call freephone 0808 165 0008 Filter Cartridge Replacement Period Franke FilterFlow filter...

Страница 3: ...from home If you are planning to leave the premises where the filter is installed for an extended period it is advisable to isolate the filter system Turn off the water supply to the filter using the...

Страница 4: ...ions for the two bracket supporting screws J Screw in both screws leaving their heads protruding approximately 3mm to allow the bracket E to be easily lifted on and off the screws L Zurich Tap Supplie...

Страница 5: ...ector may result in a water leak or failure of the joint Turn the water on Check to make sure all the connections are secure Close the stop valve and turn the lever of your filter tap to the ON positi...

Страница 6: ...or a few moments This may continue for 2 to 3 weeks until the cartridge is fully conditioned Tiny black specks in the water Tiny black specs may appear initially in the water These are harmless partic...

Страница 7: ...he complete cartridge to Franke FilterFlow for recycling Should you decide to return the cartridge please allow it to dry naturally and return it in the original packaging 1 Locate the shut off valve...

Страница 8: ...sed by negligent use or care misuse neglect careless operation or handling of the filter system which is not in accordance with the Franke FilterFlow operating guidlines Use of the filter system for a...