![Franke F3D Frozen French Fry Dispenser Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/franke/f3d-frozen-french-fry-dispenser/f3d-frozen-french-fry-dispenser_operating-manual_2327205013.webp)
F3D Operating Manual
Page 13
§
Wipe down, sanitize and dry the freezer interior and the chute
doors.
Tip: The chute door frames are hinged. You can gently push them
open to fully clean the chute doors and door frames.
§
Wipe down and sanitize the side basket hanger rack.
§
Remove the main drip tray; wash and sanitize it in the sink.
§
Wipe down and sanitize the surface beneath the drip tray.
§
Close the freezer door.
Note: For stores that operate on a 24-hour schedule, the freezer
should be shut down for a minimum of 2-3 hours per day.
7
Preventative Maintenance
1 Clean the Condenser Coil
Periodically, remove the front louvered panel to access the condenser
coil. Use a soft-bristled cleaning brush to gently remove dust and
debris in and around the coil.
CAUTION!
Verify the freezer is disconnected from the power source before
attempting any preventive maintenance.
Care should be taken to avoid physical contact with the fins on the
condenser coil or any related refrigeration lines. The fins on a
condenser coil are very sharp, and certain refrigeration lines can be
very hot resulting in possible cuts and/or burns. Gloves are
recommended when accessing the internal components of any
refrigerated equipment.