5. Application
Hygiene washing unit for wall-mounting, for connecting to warm water or cold water,
electrical and water connections located at the bottom. Premounted ready-for-
connection, for concealed mounting from the front.
6. Technical Specifications
7. Scope of Delivery
Completely pre-mounted
8. Dimensions
9. Installation Example
10. Assembly Instructions
Warning!
• Secure the electric connection with an earth leakage circuit breaker (RCD) for a
maximum nominal fault current of 30 mA.
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
☞
To protect the tiles, use masking tape when marking and drilling. Drill at low speed.
☞
Depending on the composition of the wall, special wall dowels may have to be used
(to be provided by the customer).
10.1 Mark the boreholes for the hook-in strip according to the dimensions.
10.2 Drill according to the markings.
10.3 Insert the dowels.
Minimum flow pressure:
1.0 bar
Recommended flow pressure:
1–5 bar
Maximum operating pressure:
10 bar
Calculation flow rate:
0,07 l/s
0,07 l/s
Supply voltage:
230 V AC
Power consumption:
3 W
Type of protection:
Electronic IP 68, solenoid valve IP 40