16. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and
regulations applicable on site, the fitting must be maintained and serviced at regular
intervals.
Perform maintenance on the following components:
• Aerators
• Filters (see
Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
Remove the cover plate
To perform maintenance work it is necessary to remove the cover plate.
16.1
Remove the screws (c) from the bottom of the cover plate.
16.2
Pull the cover plate (b) down and forwards and then unhinge upwards.
16.3
Close the flow volume regulator (see
).
16.4
Trigger the valve.
17. Replacing Filters
Filter for water volume regulator
17.1
Remove the cover plate (see
17.2
Unscrew the locking screw (c) on the flow volume regulator.
17.3
Replace the filter (d).
☞
Important!
Ensure that the filter is positioned the right way round.
17.4
Reassemble in the reverse order.
Filter solenoid valve
17.5
Remove the cover plate (see
17.6
Dismount the solenoid valve.
17.7
Replace the filter (c).
☞
Important!
Ensure that the filter is positioned the right way round.
17.8
Reassemble in the reverse order.