16. Replacing the Plastic Hose
16.1
Remove the cover plate (see
16.2
Press the ring in the arrow direction.
16.3
Pull out the plastic hose.
16.4
Apply a slight pressure to push the plastic hose inwards to the stop.
16.5
Open the water volume regulator (
16.6
Mount the cover plate.
17. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Fault
Cause
Remedy
Water does not flow
– Water supply interrupted
➯
Restore it
– Water flow regulator closed
➯
Open it
– Solenoid valve faulty
➯
Replace it
– Opto-sensor faulty
➯
Replace it
– Electronic module defective
➯
Replace it
Water flows conti-
nuously
– Solenoid valve dirty
➯
Clean it
– Solenoid valve faulty
➯
Replace it
Water flow too weak
– Water volume regulator not fully
opened
➯
Open it
– Supply pressure too low
➯
Check it
– Flush volume adjustment incorrect
➯
Adjust it
Water flow too large
– Flush volume adjustment incorrect
➯
Adjust it
Содержание 2000101096