2.5. Pre-utilisation check

Check, that the seals are in good condition, that the
door closes correctly, that the glasses are not
damaged.

2.6. Mounting the levelling feet

Fit the 3 screws  and the 3  caps supplied (on the
burner) into each leg of the stove (fig. 4).

2.7. Levelling

It is essential to ensure that the appliance sits level
on the floor. Adjust the levelling feet. Use a spirit level
across the burner pot to check the level (fig. 4).

2.8. External tank

When the stove is connected to an external or remote
tank, it must be secured to the floor. The bracket is
included (fig. 6).
A barometric fuel tank should not be positionned where
it will be in the direct rays of the sun or adjacent to a
source of intense heat.
If the tank is more than 8 ft (2,5 m) higher than the stove
a pressure reducer must be installed on the oil line (see
fig. # 5).
If the tank is lower than the stove a lift pump will have
to be utilized (see fig. # 5).
A clearance of 6 “ (15 cm) must be maintained between
the external/remote tank and the stove.

1

3

4

6

2

7

1

5

3

6

2

7

1

2

3

Figure 4 - Levelling

1 - Spirit level
2 - Screw
3 - Cap

Figure 5 - Oil supply

1 - 8 ft max.
2 - At least 9,5 in.
3 - Oil Tank
4 - Filter

5 - Suction pump with re-
serve
6 - Pipe Ø 3/8" O.D.
7 - 0,15m minimum

1

2

3

Figure 6 - Bracket

1 - Rear foot

2 - Bracket

3 - Foot fixation screw

Document n° 952-3 EN ~ 02/03/2000

Continental

Poêle à combustible liquide

Notice de référence

5

Содержание Le Continental 174 07 53

Страница 1: ...lges 59660 MERVILLE Phone 03 28 43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Subject to modifications Le Continental Oil fired stove Model 174 07 53 ANSI UL CAN CSA approved Fran ais English D...

Страница 2: ...ntenance of the stove 7 Trouble shooting 8 Spare parts 9 CONTENTS Page Page FRANCO BELGE congratulates you on your choice FRANCO BELGE which has been granted the ISO 9001 certification guarantees the...

Страница 3: ...nal heat output Btu h 19 600 kW 5 75 Oil consumption at nominal speed USgal h 0 198 l h 0 75 Chimney draft w c g 0 06 Pa 15 7 9 8 1 2 3 4 5 6 10 11 12 13 Fig 1 Description 1 Cover 2 Top plate 3 Flue b...

Страница 4: ...y Ensure that the flue has sufficient draught refer to technical details Minimum flue diameter 10 cm 4 I D The chimney must be at least 4 5 m 15 ft high The flue must not be shared with any other appl...

Страница 5: ...uel tank should not be positionned where it will be in the direct rays of the sun or adjacent to a source of intense heat If the tank is more than 8 ft 2 5 m higher than the stove a pressure reducer m...

Страница 6: ...float regulator are very sensitive The hight and the low setting screws must never be turned more than a 1 4 of a turn at a time in any direction from their initial setting When making any adjustment...

Страница 7: ...Recommendation The adjustment of the stove has been made at the factory and checked by your installer Any anomaly of operation should be reported to him at once This room heater is a hight heat produ...

Страница 8: ...y Fill tank Insufficiant draft Call your installer Flame is excessely large smokey and sooty Fuel adjustment made too quickly Return control knob to 1 wait for normal combustion catalyser should glow...

Страница 9: ...10 Regulator support A B C 01 38 240806 10 Support A B C 01 39 228615 Square A B C 02 40 259027 Fixing plate A B C 02 41 260567 Heat shield A B C 01 42 276003 Descriptive plate A B C 01 43 300120 59...

Страница 10: ...71 194403 Catalyser body A B C 01 72 199204 Regulator filter A B C 01 74 236707 94 Bracket A B C 01 75 988803 Complete door Y B 01 75 988804 Complete door L A 01 75 988850 Complete door J C 01 76 109...

Страница 11: ...Fig 9 Document n 952 3 EN 02 03 2000 Continental Po le combustible liquide Notice de r f rence 11...

Страница 12: ...lting from the use of fuel not recommen ded in our instructions Parts which are damaged by external causes such as unadapted chimneys thunderstorms damp faulty pressure or fail in pressure thermic ano...

Отзывы: