WARNING
The appliance must be installed in compliance with Current Building Regulations.
Incorrectly installed, this appliance can be dangerous
and possibly cause serious accidents.
The manufacturers responsibility shall be limited to the supply of the equipment.
❑
1. Product information
1.1. Package
•
1 package : Stove complete.
The ceramic coals are supplied inside the combustion
chamber.
•
1 package : Balanced flue
1.2. Optional equipment
Balanced flue elbow 135° (code 72630).
1.3. General characteristics
Model
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 05 06 . . . . . . . 154 05 07
GAS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Natural gas . . . . . Propane LPG
Type/category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G20 /
I
2H
. . . . . . . G31 /
I
3
P
Gross calorific value (heat input) . . . . . . . . . . . . . kW
. . . . . . . . . 4.2
. . . . . . . . . . 3.9
Nominal output . . . . . . . . . . . . . . . . . . . . . . . kW
. . . . . . . . . 3 . . . . . . . . . . . 3
Supply pressure . . . . . . . . . . . . . . . . . . . . . mbar
. . . . . . . . . 20 . . . . . . . . . . . 37
Burner pressure . . . . . . . . . . . . . . . . . . . . . mbar
. . . . . . . .
18,5 . . . . . . . . . 35,5
Gas rate . . . . . . . . . . . . . . . . . . . . . . . . . m
3
/h
. . . . . . . .
0,44 . . . . . . . . . 0,16
Injector size . . . . . . . . . . . . . . . . . . . . . . . bray
. . . . . . .
18 / 280 . . . . . . . 18 / 120
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . Kg
. . . . . . . . . 55 . . . . . . . . . . . 55
420
550
409
398
Ø 153
Figure 1 - Dimensions in mm
Model. 154 05 06 / 154 05 07
Balanced flue Gas stove
Technical manual
3