2.9. Preparing the insert fire
Figure 9
When the chimney hearth hight is less than 621 mm :
-
Remove the glass door.
-
Remove the flue damper control and flue damper
(2 bolts).
-
Remove the flue collar (2 screws).
2.10. Setting
Figure 11
-
Slide the insert fire in the chimney hearth by lining up
the cast iron fascia with the front of the chimney
casing.
-
Replace the cast iron flue collar by fitting it in the flue
pipe and temporarily refit the flue damper control.
-
Refit the flue damper control and the flue damper. The
handle of the flue damper control must point upwards
when the damper is closed (fig. 10).
If the chimney has a
wooden beam
, it must be
protected by fitting underneath it a metal strip (fig. 11),
with isolating fibre of air pocket between the beam and
the strip.
2.11. Electrical connection
The electric installation must be carried out in
accordance with the regulation in force.
634 10 47 only
Electrical connections should not be made until all other
installation operations are completed (fixing, assembly,
etc...).
Complies with :
- Low tension Directive 73/23/CEE, under standard
NF-EN60335-1.
- Electromagnetic compatibility Diretive 89/336/CEE
The fans electrical requirement is 230 V ~ 50Hz. Plug in
the power cable on a wall socket with a link to an earth
socket and protected by a 1 A fuse-wire.
Please note : When using a variator of speed (optional),
connect the fans on the variator
(Use only the
FRANCO BELGE variator ref. V634 10 37).
Technical manual “646”
9
“Ubinas” - ref. 634 10 47/634 10 48
Installation instructions
Figure 9 - Preparing the insert fire
Figure 10 - Flue damper control
Figure 11 - Setting
2 3 0 V ~ 5 0 H z
L
N
V
T
V
B N
B U
B K
B U
B K
G N Y E
Figure 12 - Electrical wiring
T
: Safety thermostat
V
: Fans
V-
V
: Automatic speed
control (optionnal)
Ph
: Phase
N
: Neutral
BU
: blue
BN
: brown
BK
: black
GN
YE
: green/yellow
Beam
protection