background image

 
 

6 - Operating Instructions 

 

This equipment is designed for use out of doors, in free air. Never place anything on, or cover the 
searchlight when in use as this may present a hazard. 

 
The searchlight can be remotely positioned via the joystick control panel, with the facility for 

movement up, down, left and right. When in the desired position the joystick should be released so 
that it returns to its’ home position, dead centre. 

 
The beam of the searchlight can be adjusted to give a variety of beam types. Using the yellow 

remote focus button on the joystick panel, the desired beam can be achieved for any particular 
application. The beam will move continuously through ‘spot’ to ‘flood’. In order to fix the beam type; 

simply release the button at the desired position.  
 

The heaters specified on this equipment are self-regulating and will shut off when they reach the 
dew point temperature. 

 
This product should not be used for any purpose other than for which it was designed. Any 

modifications to the product should not be undertaken without consulting the manufacturer. 
 

Setting to Work 
 

Safe service in use necessitates the strict observance of the following precautions. 

„

 

Any article fabricated from quartz or glass is inherently fragile and care should 

therefore be taken, at all times, when handling lamps; 

„

 

Eye protection must be worn when handling lamps that have been removed from their 

packaging materials. The protective jacket should not be removed from the lamp for 
safety reasons, as there is a remote possibility of the lamp shattering violently, 

especially if it is subjected to mechanical shock or vibration; 

„

 

Always isolate the equipment from the supply before inserting a lamp; 

„

 

Before inserting the lamp ensure that all contacts are clean. Contacts must be 
renewed at the slightest sign of corrosion. Sanding or filing down corroded areas is not 

recommended as this will only make the conducting surface between the pin and 
lampholder smaller, thus causing the lamp to overheat;  

„

 

Do not twist or bend the fused quartz bulb when fitting the lamp as mechanical 
stresses MUST be avoided; 

„

 

The lamp must be capable of unimpeded expansion when it warms up to operating 
temperature. Mechanical forces must not be applied to the fused quartz bulb; 

„

 

Before the protective jacket is removed, suitable protection must be worn i.e face mask 
and gloves with wrist protection;

 

„

 

Never touch the quartz bulb with bare hands, as fingerprints will make the glass cloudy 

and cause a severe loss of light. This may also cause recrystallisation and thus 
weaken the bulb material. Should the bulb be inadvertently touched, remove 

fingerprints with methylated spirit and a clean, soft paper towel. The bulb should then 
be wiped with distilled water. NOTE: ALWAYS WEAR MASK AND GLOVES DURING 

CLEANING);

 

Содержание FH380

Страница 1: ...ght Product Reference Number A6076 FH380RC Twin Head 1200w 220v Manufacturer s details Distributor details Francis Searchlights Ltd Union Road Bolton Lancashire BL2 2HJ UK Tel 44 0 1204 558960 Fax 44 0 1204 558979 http www francis co uk E mail sales francis co uk Manual Part Number C24945 23 11 11 Issue 4 ...

Страница 2: ...ety Precautions 3 Technical Information 4 Unpacking and Installation Instructions 5 Electrical Installation 6 Operating Instructions 7 Fault Finding 8 Maintenance and Servicing 9 Wiring Diagram General Assembly 10 Spare Parts List ...

Страница 3: ...optimum performance and service life The Francis FH range combines features proven over many years service in the most hazardous conditions in both marine and land installations In order to prolong the life and performance of your product we recommend that you only specify Francis Searchlights spare parts This will also ensure that any warranties on your equipment will not be invalidated Informati...

Страница 4: ...re a safe working environment Never attempt to clean a lamp whilst in use Searchlights get hot Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the searchlight off Never place anything on or cover the searchlight when in use Ensure the lamp has cooled sufficiently before removal If undue force appears necessary to remove the lamp the equipment should b...

Страница 5: ... R P control gear protected to IP66 Colour Temperature 5 400K Luminous Flux 105 00 The 240v searchlight also performs to the following optical data Metal Halide light source G38 Lamp Wattage 1200 Watts Supply voltage 220 240V Peak Beam Candlepower 28 500 000 lux with standard Glass Peak Beam Candlepower 22 800 000 lux with UV Glass Range 5343 metres Range UV 4274 metres Divergence 2 5 Temperature ...

Страница 6: ...eing installed Installation procedures should be adhered to in order to ensure a safe working environment and reduce the risk of damage or personal injury Preparing the Mounting Position Mark out and drill the fixing holes through the deck 4 Holes Ø12 5mm on a 350 PCD If anti vibration mounts are to be fitted the fixing holes for the mounts should also be marked out and drilled Prior to manoeuvrin...

Страница 7: ...al supply using suitably sized cable 3 If the searchlight is located a considerable distance from the supply provision must be made in the cable size in order to overcome the voltage drop The following table should be used for indication purposes only Searchlight 240v 1 2Kw Cable Size mm Distance Max 1 5 62 MTRS 2 5 101 MTRS 4 0 160 MTRS 6 0 249 MTRS 10 0 417 MTRS 4 Whenever possible cable termina...

Страница 8: ...d to the motor gearbox control panel and the searchlight The searchlight has been pre wired with 3 meters of cable from the gearbox to junction box to the Control Gear Enclosure Cables required to be connected by the customer 8 core 1 5mm cable from the Junction Box to the Control Panel 12 core 0 5mm cable from the Junction Box to the Control Panel The searchlight head is pre wired along with the ...

Страница 9: ...andling lamps Eye protection must be worn when handling lamps that have been removed from their packaging materials The protective jacket should not be removed from the lamp for safety reasons as there is a remote possibility of the lamp shattering violently especially if it is subjected to mechanical shock or vibration Always isolate the equipment from the supply before inserting a lamp Before in...

Страница 10: ...prevent the fingers coming into contact with the lamp position the two pins above the holes in the lampholder Gently push the lamp into the lampholder and remove the protective sleeve Replace the light shield spill ring and front bezel assembly ensuring the thumbscrews are securely fastened Testing Upon correct installation and connection to an electrical supply the equipment can be tested in orde...

Страница 11: ... the lamp If noticeable damage to filament is present the lamp will have failed The lamp can also be checked for continuity using a multi meter Replace lamp ensuring all precautions and instructions previously outlined in this manual are adhered to Failure of Remote Focus Causes 1 Power not supplied 2 Faulty connections 3 Failed motor Remedy 1 Check voltage at supply If no supply present fault is ...

Страница 12: ... inside and out using a proprietary glass cleaner or metal polish Clean the reflector if required Check the reflector mounting gaskets If signs of corrosion or damage are evident replace as necessary Ensure that the lampholder is free from corrosion or other damage It is advisable to check all seals and gaskets for signs of degradation Renew if necessary The searchlight is fitted with a breather u...

Страница 13: ...General Assembly Drawing Number Description A6076 FH380RC 1200w 240v Twinhead Searchlight G A C24946 FH380RC 1200w Twinhead Wiring Diagram C24947 Control Gear Assembly C24949 Junction Box Assembly Control Panel Back To Top ...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ... Assy C22287 00 Tilt Motor C22380 00 Microswitch no lever C22382 00 Microswitch with lever C24030 01 I Drive Pan Speed Controller C24060 01 I Drive Tilt Speed Controller C23530 00 PSU C22301 00 Pedestal Top Sealing Gasket C26185 00 Pedestal Cover Gasket In order to prolong the life and performance of your product we recommend that you only specify Francis Searchlights spare parts This will ensure ...

Отзывы: