6. INSTALLATION

6.1 RULES FOR INSTALLATION

  READ CAREFULLY!

• 

The minimum safety distance indicated in the illustration 

must be observed.

• 

If you install the unit heater above the door, place it as close 

to the edge as possible on the upper part of the door. Make 

sure that the suction and exhaust of the curtain are not ob-

structed in any way and that the air flow can freely flow into 

the room.

• 

The unit heater is connected to the main power supply by 

a cable with a plug. Please ensure that the power supply 

socket is within a maximum distance of 1.5 m.

• 

Dowels for wall installation - not supplied with the deliv-

ery, 4 pieces of M8 screws for fixing - not supplied with the 

delivery.

1. Attach the brackets to the wall

2.  Screw the unit heater (curtain) onto the brackets using the 

screws (supplied with the delivery)

Detail of the connection of the unit heater to the brackets

                TECHNICAL SUPPORT

To install the brackets, use the size 5 Allen key.

 READ CAREFULLY

• 

Please ensure that the exhaust pipe is not obstructed in 

any way and that the air can circulate freely in the room.

• 

The unit heater is connected to the main power supply by 

a cable with a plug. Please ensure that the power supply 

socket is within a maximum distance of 1.5 m.

• 

The minimum safety distance of 30cm between the unit 

and flammable objects must be observed in all directions.

min. 150 mm

min. 50 mm

max. 1800 mm

Содержание Harmony One Evo Series

Страница 1: ...Harmony One Evo EN Harmony One Evo 600 Harmony One Evo 900 NT 1583 A 07 2019 ...

Страница 2: ...n installation according to this manual the product can be used safely For product evaluation the harmonised standards specified in the current EC Declaration of Conformity have been used To read the full EC Declaration of Conformity in force please visit www france air com This manual contains important instructions and safety instructions To ensure proper operation and user safety read and obser...

Страница 3: ...r unpacking check that 1 The designation on the packaging corresponds to the label on the unit heater 2 The unit heater is not damaged The electric unit heater can be used in many different ways Thus it can be placed above the door windows or on the wall For installation please observe the instructions below As this is a heating unit it is necessary to comply with the basic heating rules To calcul...

Страница 4: ...t supplied with the deliv ery 4 pieces of M8 screws for fixing not supplied with the delivery 1 Attach the brackets to the wall 2 Screw the unit heater curtain onto the brackets using the screws supplied with the delivery Detail of the connection of the unit heater to the brackets TECHNICAL SUPPORT To install the brackets use the size 5 Allen key READ CAREFULLY Please ensure that the exhaust pipe ...

Страница 5: ...nnot be connected with an extension cord The maximum curve of the power cable is 30mm 6 3 CONTROL PANEL Remote control connection The remote control does not need to be adjusted it is supplied pre set by the manufacturer The control is powered by a 12V electric battery LR23A the electric batteries are included with the delivery It is possible to link up to 60 units to one control The perimeter of ...

Страница 6: ...ne time turns the curtain off activates a cooling function automatically and cools the electric heater for 30 seconds then automatically turns off The cooling of the current electric heating is indicated by a flashing speed 1 on the integrated panel Programming pairing This function is activated 30 seconds after the curtain is turned on if the curtain was not connected to the front main power sup ...

Страница 7: ...ol does not work The air curtain does not receive any control signal from the remote control Check if the batteries are dead Check the polarity of the batteries in the remote control Check if the remote control is too far from the curtain and if there is any signal intervention The heating switches off spontaneously The heater is overheated The electric heater overheats because the air flow is not...

Страница 8: ...cessory used Place of installation Serial number Installation conditions including electrical conditions Operating time Detailed error description 10 2 DEACTIVATION OF THE PRODUCT BEFORE DISPOSING OF IT Even old products contain reusable materials Transport this type of material to the secondary material collection centre It is pref erable to allow the product to be disposed of in the specialised ...

Отзывы: