5.
Check that the connection between the roof module DC cord and wall module DC cord
is secure.
6.
Reinstall the cover panel and body covers.
7.
Connect the power cord.
Cause: The motion detector is broken.
To determine if the motion detector is broken, disconnect the power cord of the pod and
reconnect it. If the fans and light switch on normally and go off after 8 minutes, but do not
switch on when a person enters the pod, the motion detector is broken.
Solution: Contact Framery support for a replacement part.