44
ATTENTION
:
1.
Due to safety reasons, legislation forces a room of at least 1 m³ per 8 g refrigerant for such
equipment. For 150 g propane, the minimum allowed room size would be 18.75 m³.
2.
Coolant: Risk of fire/risk of poisoning/risk of material damage and damage to the appliance. The
appliance contains refrigerant which, although it is environmentally friendly, is flammable R290.
Failure to dispose of it properly may result in a fire or poisoning. Dispose of the appliance properly
and do not damage the pipes in the refrigerant circuit.
Type of refrigerant: R290
Quantity of gas: 150 g
ODP (Ozone Depletion Potential): 0
GWP (Global Warning Potential): 3
Risk of explosion or fire. Remove any cigarette lighters and matches from pockets.
Do not place the dryer near open fires and ignition sources.
Your dryer is fitted with systems that continuously perform checks during the drying process to take the
necessary measures and warn you in case of any malfunction.
WARNING:
If the problem persists even if you have applied the steps in this section, please contact the your
dealer or an Authorized Service Provider. Never try to repair a nonfunctional product.
PROBLEM
REASON
SOLUTION
The drying process takes a long time.
The surface of the lint filter
might be clogged.
Wash the filter with lukewarm water.
The heat exchanger might be
clogged.
Clean the heat exchanger
The ventilation grills in front
of the machine might be
closed.
Open the doors/windows to prevent the
room temperature from rising too much.
There might be a layer of
limescale on the humidity
sensor.
Clean the humidity sensor.
The dryer might be
overloaded with laundry.
Do not overload the dryer.
The laundry might be
insufficiently spun.
Select a higher spin speed on your
washing machine.