8. CONTROL PANEL
1. ON/OFF SWITCH
– press to turn on/off the device
2. SELECTION OF FUNCTIONS
– press to select the function of cooling, dehumidifying or ventilation
3. SETTING OF THE TEMPERATURE
– (UP) cooling mode (+): press to increase by 1°C to the maximum temperature of 30°C
4. SETTING OF THE TEMPERATURE
– (DOWN) cooling mode (-): press to lower the temperature by 1°C to the maximum tempe-
rature of 17°C
5. LCD
– the display shows the current settings of the device. The display also shows error codes; when an error occurs, see “ERROR
CODES”
6. FAN SPEED
– press to select low, medium, high or automatic fan speed. When the AUTOMATIC function is selected, the fan spe-
ed mode will be automatically selected, depending on the difference between the ambient temperature and the set temperature.
7) TIMER
Timer – turning on the device:
used to automatically turn on the device after a specified time
• Press the timer button to set the desired time
• After the specified time, the device automatically turns on
• If the power button is pressed before the set time, the device will start immediately, the time set on the timer will be cancelled.
• While setting the timer, it is possible to set the functions and speed of the fan.
Timer – turning off the device:
used to automatically turn off the device after a specified time
• Press the timer button to set the desired time
• After the specified time, the device automatically turns off
• If the power button is pressed before the set time, the device will turn off immediately, the time set on the timer will be cancelled.
8) NIGHT MODE
• Press the night mode button in the cooling mode. In this mode, the air conditioner will increase the temperature by 1°C after an
hour and by a maximum of 2°C after 2 hours.
• Press the night mode button again to cancel the settings.
9) OSCILLATION
Press the oscillation button to turn on the oscillation of the cold air outlet. Press again to stop. The shutters will return to the star-
ting position when the device is turned off.
10) ALARM
When the water tank is full, the “E4” error is displayed. To resume operation of the device, first remove the rubber stopper from the
fixed water drain connection and pour out the water. The “E4” error will disappear when the water is poured out. When the “E4”
error disappears, the device can be restarted by pressing the power button.
FRAL SUPER COOL FSC09C
PORTABLE AIR CONDITIONER
17
INST. _PL_EN_DE_FSC09C_WER.3