7

   

box of the telephone line.
•  The control unit must be installed on the wall in a position that makes it easy to access the  

 

electric cables, telephone cable, system alarm harness as well as to perform maintenance    
on the control unit.
•  Do not install the control unit and its modules in places with extreme temperatures and    

 

humidity. For example, don’t place the keypads near heat sources such as radiators    

 

or under direct sunlight, which can affect the liquid crystal display. Place the control    

 

 

unit and its accessories in a dry room and avoid closing the vent slots which can create a    

 

block, even partially, of internal ventilation.

4.1 Installation of the BUS RS485

The connection is performed by means of 2 conductors plus the ground conductor (negative). It is 
recommended to use a shielded cable. The ground is the same used to feed the devices.
Take note that the bus can have parallel branches and shunts, according to the following rules:

•   the total length of the bus harness (the addition of all branches and their shunts) must not  

 

 

exceed 1500 m.

•   insert two 120 ohm 1/2W termination resistances on the bus, one resistance between the  “+”    
 

and “-“ terminals of the control unit and another resistance at the end of the longer pathway. 

Minimum cable sections:

Distance from the control unit  

“BUS+” e “BUS-” conductor

Common ground conductor

Up to 400 m

0.22 mm

2

0.22 mm

2

Up to 700 m

0.22 mm

2

0.5 mm

2

From 700 m to 1500 m

0.44 mm

2

0.75 mm

2

See the following example:

120 Ohm resistance
between the BUS+ terminal and
BUS-terminal of the last 
peripheral unit.

120 Ohm resistance
between the BUS+ terminal
and BUS- of the control unit

   

   

Содержание CE2N-416

Страница 1: ...CE2N 416 Installer and user Programming Manual...

Страница 2: ...age 11 13 8V EXT_SIR live output of battery recharging page 11 V_INT SIR live output of internal sirens page 11 REF 12V reference output page 12 Bus terminals for serial line connection page 12 Out 1...

Страница 3: ...page 37 8 7 Exclusions page 37 9 Reset page 39 9 1 Reset the keypad serial number with a zero address page 39 9 2 Restore factory settings page 39 User manual 10 Parameters that can be programmed by...

Страница 4: ...carro Radioindustrie SpA declares that the system conforms to the essential requirements and other provisions provided by European directive 2004 108 EC EMC and CEI EN 50130 4 CEI EN 61000 6 3 CEI EN...

Страница 5: ...be programmed Activation time activation mode activation delay and possibility of associating key user is also possible 3 access levels Installer 1 master user 8 users which can be modified The lines...

Страница 6: ...mA OUT 1 5 50mA B 500mA 13 8V EXT_SIR 500mA N B The total absorption at the outputs 13 8V EXT_SIR and V_INT_SIR and BUS power must not exceed 500mA Lead battery 2Ah 12V 3 CE2N 416 CONTROL UNIT LAYOUT...

Страница 7: ...2 conductors plus the ground conductor negative It is recommended to use a shielded cable The ground is the same used to feed the devices Take note that the bus can have parallel branches and shunts a...

Страница 8: ...of te lephone line Jumper J2 Jumper for the connection of the anti tear button If the jumper is not used bridge it closed by default S2 With S2 in the ON po sition the control unit Tamper is active an...

Страница 9: ...tor for the connection to MOD USB which is used to carry out Firmware updates of the control unit J800 J801 These 2 connectors are necessary to install and connect the speech card optional For the spe...

Страница 10: ...rammed Programmed by default as an intrusion alarm output Max current 500 mA GND Ground negative of the power supply point REF Live output which can be programmed Programmed by default as a reference...

Страница 11: ...le balancing example Single balancing example Normally closed example Normally open example B 12V live outputs always available even when the control unit is OFF The cables to feed the detectors and o...

Страница 12: ...output connection terminals Open collector signal output By default there is a negative at the output in accordance with the programmed activating event Example to activate a tone signal by an extern...

Страница 13: ...s phase we recommend not connecting the wires to the V_INT SIR terminal and REF terminal in order to prevent the activation of the indoor and outdoor sirens Remember to connect the siren controls when...

Страница 14: ...amming the Master code refer to the User Master section in paragraph 10 The CE2N 416 system allows the user to have 1 master code with a variable length between 2 and 7 figures This code is allowed to...

Страница 15: ...menu you can set the installer code Default code 0000000 Ref 8 4 page 35 from this menu you set the date and time which will be displayed by the keypad Ref 8 5 page 36 this menu displays the event li...

Страница 16: ...how sensitive the line must be in reception Impulses the number of necessary impulses that the line must receive is set before the control unit generates an alarm Int time the setting of the integrat...

Страница 17: ...ion contact at the line input without using any other additional analysis card Def Load V yes X no all the default parameters of this line type will be loaded Sensitivity value expressed in millisecon...

Страница 18: ...nd the alarm LED on the keypads The alarm is visualized on the display Only the outputs associated to this line are activated The alarm is not detected if you are within the installer menu 24 hour lin...

Страница 19: ...ss example from page 13 Assigning a name to the line Each line can be sociated with a name which is different than the one set at the factory such as LINE01 LINE02 LINE16 This function facilitates the...

Страница 20: ...trol OUT 1 open collector output OUT 2 open collector output OUT 3 open collector output OUT 4 open collector output OUT 5 open collector output Output status By this item you set the output stand by...

Страница 21: ...output ATTENTION the words ON and OFF at the end of the writing identifies if the event must control the output with an armed control unit ON or a disarmed control unit OFF Output settings Activation...

Страница 22: ...rtitions The system offers different insertion types depending on the needs The system lines can be gathered in partitions Therefore a partition is a logical gathering of lines such as the night and d...

Страница 23: ...manual output status Channel type By this item you can program the channel operation type Vocal send a vocal message to warn the user that an alarm has been released ATTENTION if the vocal synthesis c...

Страница 24: ...corded ones Anti burglar alarm Intrusion alarm Emergency alarm First aid alarm Technological alarm Tamper alarm Lack of network failure of the control unit And the custom messages Custom message from...

Страница 25: ...made by the user for the alarm in progress Name each channel can be named again this function facilitates the user of the end user Paste on among the options that can be selected it is possible to pa...

Страница 26: ...age from a specific channel It is normally used to record the address with the personal details of the system owner Custom message from 1 to 8 maximum length of 5 seconds if the pre recorded channel m...

Страница 27: ...wers Line control when activated the dialler continuously monitors the presence of the phone line an alarm condition can be generated DTMF confirmation if this function is active all the following cal...

Страница 28: ...orea Poland Thailand Bulgaria France Iceland Luxembourg Portugal Tunisia China Germany India Malaysia Singapore U S Canada Remote optional functions of the control unit The dialler can be customized w...

Страница 29: ...ital B Select the events that will trigger the virtual dialler Alarm lines Anomalies C Select which message among the recorded ones the virtual dialler must send You can choose a preset message or cus...

Страница 30: ...he indications open line activations etc on the keypad display KEY False code alarm enables the generation of an alarm in the event that a false code is entered repeatedly or a non acquired key is bro...

Страница 31: ...LCD display and a status LED Up to 4 remote keypads can be connected to the BUS of the CE2N 416 control unit Acquisition Cancellation Acquire Keypads Names Configuration Select keypad keypad 00 Keypa...

Страница 32: ...for each keypad by pressing the F1 F2 F3 F4 keys without entering any valid code This function allows any user to perform the functions quickly and easily These functions can be defined during the in...

Страница 33: ...super keys with different controls in accordance with the installation place and the personnel s need Backlighting time In this programming phase you can adjust the keypad backlighting to enter the d...

Страница 34: ...0 the second will be the number 1 etc Attention Do not install the CH BUS module near the magnetic fields for example transformers dimmers etc that may affect the operation The minimum distance of in...

Страница 35: ...er a few seconds all the acquired modules will be displayed Cancellation of the Line Module From this menu item you can cancel all modules which are removed from the system After selecting the Cancell...

Страница 36: ...lk Test Tamper Channel 32 Channel test Channel 1 Channel 32 DTMF reception test Channel 1 Test Phone number Phone number Phone number Phone number Lines being tested The CE2N 416 control unit allows y...

Страница 37: ...l generate a tone every time that the contact is activated and the activation will be recorded on the display Press the key no 5 on the keypad to reset the alarm Channel test The control unit allows y...

Страница 38: ...US will display the LED green permanently on all armed while the keypad will display the indication of the zone s excluded and even if the control unit is compeltely armed the system will display the...

Страница 39: ...ddress The following is the procedure to cancel the serial number of the zero keypad 1 Start with the jumper S2 in the OFF position as shown in the figure 2 Simultaneously press and hold RESET and DEF...

Страница 40: ...ve users in the system Ref 10 4 page 44 from this menu the MASTER user can modify the phone book numbers Ref 10 5 page 45 this menu displays the event list recorded by the control unit with relevant d...

Страница 41: ...phone calls When the call is received from the dialler the user enters the confirmation code on the phone keypad by default 555 in accordance with the programmed phone options the control unit will d...

Страница 42: ...ions Enter the submenus to define the code powers It can be defined what the code can activate and deactivate which partition it can activate or deactivate and which areas of the houses it can exclude...

Страница 43: ...partial activations the generated user can manage Remote access With this function the MASTER user defines if the user code is enabled for all its functions to manage the system remotely via telephon...

Страница 44: ...can be brought up to the reader Continue the sequence for all the keys that you want to memorize After all keys are memorized press X to finish the procedure Now all keys have been acquired and the al...

Страница 45: ...e various users master and installer The following signalizations are added to the dialer when a call is sent T line tone A lifting up O engaged C Confirmation code D Digital alarm 10 6 Test Specific...

Страница 46: ...k test mode and activate the sensors that you want to control The keypad buzzer will generate a tone every time the sensor is activated and the activation will be recorded on the display Walk test Tam...

Страница 47: ...g The control unit ignores an excluded component therefore it is possible to neither receive alarms from an excluded line nor activate the excluded outputs Line 16 Lines Line 1 Output 7 Outputs Output...

Страница 48: ...FRANCE Tel 33 1 47283400 Fax 33 1 47283421 Fracarro UK Ltd Unit A Ibex House Keller Close Kiln Farm Milton Keynes MK11 3LL UK Tel 44 0 1908 571571 Fax 44 0 1908 571570 Garantito da Guaranteed by Garan...

Отзывы: