![Fraba Vitector RAY-LG 1 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/fraba/vitector-ray-lg-1-series/vitector-ray-lg-1-series_manual_2326074009.webp)
MA NUAL
RAY- LG X 1X X
Page 9
RAY-LG x1xx Manual
Version: 20170524
EN
Installation
1.
Switch off main power to the door control unit
and clearly mark that this system is out of ser-
vice before performing any work on the system.
2.
Mount the receiver edge on one side of the
door.
Important:
Mount the receiver edge into the guiding rail
next to the door control unit (See Figure 7).
The lower end of the edges has to be at the
level of the door closed position.
3.
Mount the emitter edge across from the re-
ceiver edge. If the receiver is mounted in the
guiding rail, the emitter should be mounted in
the guiding rail opposite the receiver. Make
sure the optical elements are facing each other
(See
Alignment
, p. 5
)
.
4.
Connect the emitter with the receiver edge us-
ing the synchronization cable.
5.
Plug the connection cable into the blue plug on
the receiver edge and connect it to the door
controller (See
Electrical Connection
, p. 9
)
.
WARNING
Electrical and Mechanical Hazards
Electrical shock and unexpected door movement
can cause serious injury or death.
▪
Follow all applicable safety measures
▪
Use only specific and approved tools
▪
If the RAY-LG must be adjusted, the main
power supply must be switched off and
marked as
“out of service”.
Serious Health Risks -
Disregarding these
warnings can result in serious injury or death.
NOTICE
Mechanical Damage to the RAY-LG
▪
Do not drill additional holes into the light cur-
tain
▪
Do not over-tighten the mounting screws
▪
Mount the edges on a flat surface
▪
Do not drill directly into the mounting holes
Risk of damage -
Disregarding this notice can
lead to damage to the sensor, the door controller
and / or other devices