![FPS 9650 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/fps/9650-series/9650-series_installation-and-maintenance-manual_2326017013.webp)
9650 Valve Series
Installation and Maintenance Manual
13
5)
Remove the electrical conduit from the limit switch housing leading to the solenoid.
6)
Loosen the two capscrews holding the solenoid onto the actuator.
7)
Remove the solenoid, taking care not to lose the adapter plate, rubber gasket or two O-rings.
8)
Note whether the adapter plate is for 5/2 or 3/2 configuration from the markings.