FPI Hampton H15U-LP Скачать руководство пользователя страница 42

42

Hampton® H15U-NG/LP Direct Vent Freestanding Gas Stove

42

operating instructions

Copy of the Lighting Plate Instructions 

920-181a

Part #: 920-181a

Colours: Black on Grey,  except for parts indicated as being Red.

       Punch out .25" hole top right corner where indicated.

Size:              100%

                         w- 6.52"

                         h- 11.13"

                

Nov 04/19:    Created decal

Oct 14/21:     Standing Pilot Non-7 Day

DO NOT REMOVE THIS INSTRUCTION PLATE

NE PAS ENLEVER CETTE ÉTIQUETTE D’INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE  / POUR COUPER LE GAZ AU NIVEAU DE L'APPAREIL

CAUTION:  Hot while in operation. Do not touch. Severe burns may result. Due to high surface temperatures keep 

children, clothing and furniture, gasoline and other liquids having flammable vapors away. Keep burner and control 

compartment clean. See installation and operating instructions accompanying appliance.
ATTENTION : Surfaces chaudes lorsque l’appareil est en marche. Ne pas toucher. Risque de brûlures graves. En raison 

des températures élevées, les enfants, les vêtements et le mobilier, le carburant et tout autre liquide aux vapeurs 

inflammables  doivent  être  tenus  éloignés  de  l’appareil.  Nettoyer  régulièrement  le  brûleur  et  le  compartiment  des 

commandes. Voir les consignes d’installation et d’utilisation fournies avec l’appareil.

LIGHTING INSTRUCTIONS / CONSIGNES D’ALLUMAGE

FOR YOUR SAFETY READ BEFORE LIGHTING

POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or 

property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional 

information consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un 

incendie ou une explosion entraînant des dommages, des blessures ou la mort.

Une installation, d'ajustement, de modification, de service ou d'entretien peut provoquer des blessures ou des dommag

-

es matériels. Reportez-vous au manuel du propriétaire fourni avec cet appareil. Pour obtenir de l'aide ou des informa-

tions supplémentaires consulter un installateur qualifié, une agence de service ou fournisseur de gaz.

A)    

This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly. 

B)  BEFORE LIGHTING

 smell all around the appliance area for gas. Be sure to smell next to the floor 

     because some gas is heavier than air and will settle on the floor.

       

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do not use any phone in your building.

-  Leave the building immediately.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fire department.

C) 

Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it; call a 

qualified service technician. Force or attempted repair may result in a fire or explosion. 

D)   

Do not use this appliance if any part has been under water.  Immediately call a qualified service technician to inspect the appliance and replace 

any part of the control system and any gas control which has been underwater.

A)  

Cet appareil est muni d’une veilleuse qui doit être allumée manuellement. Respectez les instructions ci-dessous à la lettre.  

B)   AVANT LA MISE EN MARCHE

, reniflez tout autour de l’appareil pour déceler une odeur de gaz. Reniflez au niveau du plancher, car certains gaz 

sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.   

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

    • Ne tentez pas d’allumer l’appareil

    • Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le bâtiment.

    • Sortez du bâtiment immediatement

    • Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur. Suivez les instructions du fournisseur.

    • Si vous ne pouvez pas rejoindre le fournisseur, appelez le service incendie.

C)

 Ne poussez ni ne tournez la manette d'admission du gaz qu'à la main. Ne jamais employer d'outil à cette fin. Si la manette reste coincée, ne tentez 

pas de la réparer; appelez un technicien qualifié. Quiconque tente de forcer la manette ou de la réparer peut provoquer une explosion ou un 

incendie. 

D)   

N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites inspecter l’appareil par un technicien qualifié et remplacez tout 

élément du système de contrôle ou de commande qui a été plongé dans l’eau.

1)

 STOP ! Lire les instructions de sécurité sur la portion supérieure de cette étiquette.

1)

  STOP! Read the safety information above on this label.

 

2) Push in gas control knob slightly and turn clockwise              to “OFF”. Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in 

slightly. Do not force. 

3) Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow step "B" in the Safety Information above on this label. If you don't 

smell gas, go to the next step.  

4) Push in gas control knob slightly and turn counterclockwise              to "PILOT" position.

5) Push in control knob all the way and hold in until the pilot lights. Continue to hold the control knob in for about 20 seconds after the pilot lights. 

Release the knob.

6) Push in gas control knob slightly and turn counterclockwise              to "ON" position.

7) Turn on the flame switch. 

2)  Enfoncer légèrement le bouton de commande de gaz et tournez dans le sens horaire             en position OFF.  Le bouton ne peut pas être tourné 

du PILOT à OFF à moins que le bouton soit enfoncé légèrement. Ne forcez pas.

3) Attendre cinq (5) minutes pour laisser échapper tout le gaz. Si vous sentez une odeur de gaz, ARRÊTEZ! Passez à l'étape "B" des instructions de 

sécurité sur la portion supérieure de cette étiquette. S'il n'y a pas d'odeur de gaz, passez à l'étape suivante.

4) Enfoncer légèrement le bouton de commande de gaz et tournez dans le sens antihoraire              en position PILOT.

5) Pousser le bouton de commande de gaz à fond et le maintenir enfoncé jusqu'à ce que la veilleuse s'allume. Maintenir le bouton de commande de 

gaz enfoncé pendant environ 20 secondes après l'allumage de la veilleuse. Relâcher le bouton de commande de gaz. 

6) Enfoncer légèrement le bouton de commande de gaz et tourner dans le sens antihoraire              en position 'ON'.
7) 

Actionner l’interrupteur de flamme

1) Turn off the flame switch.

2) Push in the gas control knob slightly and turn              clockwise                 

to “OFF”. Do not force.

3) Turn off all electric power to the appliance if service is to be 

performed.

    You may shut off the pilot during prolonged non use periods to 

conserve fuel.

1) Fermer l’interrupteur de flamme.

2) Enfoncer légèrement le bouton de commande de gaz et tournez 

dans le sens horaire              en position OFF. Ne pas forcer.

3)  Avant d’effectuer des opérations d’entretien, couper l’alimentation 

électrique de l’appareil.

    Pour économiser le carburant, vous pouvez éteindre la veilleuse 

lorsque l’appareil reste longtemps inutilisé.

Содержание Hampton H15U-LP

Страница 1: ...hat to do if you smell gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow...

Страница 2: ...rking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Created draft Doubl...

Страница 3: ...the Lighting Plate Instructions 10 Important Message 11 Specifications 11 Mobile Manufactured Homes After First Sale 11 Before You Start 11 General Safety Information 12 Installation Checklist 12 Cle...

Страница 4: ...Horizontal Vent 19 3 8 492mm 23 1 8 587mm 20 11 16 525mm 17 1 2 444mm 14 1 4 361mm 13 5 8 345mm 24 1 8 612mm 20 13 16 529mm 18 15 16 481mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR IL...

Страница 5: ...irect Vent Freestanding Gas Stove 5 safety label Unit Dimensions with Vertical Vent 19 3 8 492mm 23 1 8 587mm 24 13 16 630mm 20 11 16 525mm 18 3 8 467mm 17 1 2 444mm 15 1 16 383mm 14 1 4 361mm 13 5 8...

Страница 6: ...nstruction and Safety Standard Title 24 CFR Part 3280 in the United States or when such a standard is not applicable ANSI NCSBCS A225 1 NFPA 501A Manufactured Home Installations Standard or ANSI A119...

Страница 7: ...e directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VEN...

Страница 8: ...converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with...

Страница 9: ...as the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if instal...

Страница 10: ...e allum e manuellement Respectez les instructions ci dessous la lettre B AVANT LA MISE EN MARCHE reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez au niveau du plancher car cer...

Страница 11: ...SA C22 1 in Canada Before You Start Safe installation and operation of this appliance requires common sense however we are required bytheCanadianSafetyStandardsandANSIStand ards to make you aware of t...

Страница 12: ...air passageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledi...

Страница 13: ...o Combustibles The clearances listed are MINIMUM distances Measure the clearance to both the appliance and the chimney connector The farthest distance is correct if the two clearances do not coincide...

Страница 14: ...training it 4 Remove the Top Control Panel Assembly by removing the three screws 7 Connect the red and black wires from the wire harness to speed controller NOTE Speed control wires should be at the b...

Страница 15: ...red to 501 red Secure all the wires using wire holder on the rear panel 16 Slide the Rear Access Panel back into position and secure with 2 screws WARNING Electrical Grounding Instructions This appli...

Страница 16: ...mbustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air for combustion and losing warm room air up the chimne...

Страница 17: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air i...

Страница 18: ...e Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black...

Страница 19: ...oCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 9...

Страница 20: ...t Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing o...

Страница 21: ...eet with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 f...

Страница 22: ...ote min 1 foot be tween90o elbowsisrequired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalverti...

Страница 23: ...runs with vertical terminations Maximum two 45o elbows If the vent is ENCLOSED in a chase min size 9 x 9 maintain a 1 1 4 clearance to combustibles May be installed in Manufactured Mobile Homes after...

Страница 24: ...the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will accommodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air...

Страница 25: ...5o elbow will seat onto both the starter collar and the 90o elbow Crimped section of rigid pipe seats into the 90o elbow Only cut the uncrimped side of pipe Dismantle all pipe sections including vent...

Страница 26: ...collar 8 Cut the 4 dia flex liner to the desired size Hint leave an extra 12 to 16 of length this willmakethefinalassemblyeasiertoworkwith 9 Secure the 4 dia flex liner to the 4 adapter with Mill Pac...

Страница 27: ...minum Vent 1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws 380 946 Horizontal Terminatio...

Страница 28: ...insulation Theminimumclearancerequirementsbetween the outer wall of the vent pipe and nearby com bustible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements from decks...

Страница 29: ...ns section c Snorkel Terminations For installations requiring a vertical rise on the exterior of the building 14 inch and 36 inch tall Snorkel Terminations as shown in Diagram 2 are available as well...

Страница 30: ...c Before connecting the vent pipe to the vent termination slide the black decorative wall thimble cover over the vent pipe then slide the Wall Penetration Heat Shield Part 946 202 over the vent pipe...

Страница 31: ...ting sys tem it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Silicon...

Страница 32: ...sleeve on the top side of the Connector Use 3 sheet metal screws to assemble these two parts 6 Push the flex pipe back up into the ceiling sup portbox centertheRetroConnector andattach it to the supp...

Страница 33: ...chimney in a convenient location as near as possible to the appliance outlet Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the...

Страница 34: ...finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten Aeration Adjustment...

Страница 35: ...and lift out Installation of LPG Conversion Kit 4 Turn control knob to the OFF position 5 Remove the Hi Low extension knob by pulling it towards you This will expose the black protection cap Remove t...

Страница 36: ...on of the DC Sparker 19 Remove the control panel by unscrewing the 2 screws 21 Plug up the Piezo hole with the plastic bushing 22 Attach the DC sparker generator connector to the valve with a screw 23...

Страница 37: ...Center Front Log e Embers f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log 4 Remove Glass front see instructions in manual 3 Remove Cast Front and set the light a...

Страница 38: ...of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top 8 Take the embers and place on the burner...

Страница 39: ...LC or UL approved may be used Thermostat Wire Table Final Check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly This includes 1 Clocking the...

Страница 40: ...away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly...

Страница 41: ...remaining from manufactur ing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning DONOTATTEMPTTOCLEANTHEG...

Страница 42: ...allum e manuellement Respectez les instructions ci dessous la lettre B AVANT LA MISE EN MARCHE reniflez tout autour de l appareil pour d celer une odeur de gaz Reniflez au niveau du plancher car cert...

Страница 43: ...e this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sou...

Страница 44: ...can cause corrosion of caps pipe and fittings It may be caused by havingexcessivelateralruns toomanyelbows and exterior portions of the system being ex posed to cold weather 4 Inspect joints to verify...

Страница 45: ...he burner tray assembly simply reverse these instructions Toremovevalvefromvalveassembly continue 13 Remove two 2 thermopile wires 14 Remove thermocouple with a 9 mm metric wrench 15 Remove pilot nut...

Страница 46: ...the list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Ope...

Страница 47: ...lTimberlineBrown 4 383 237 Top Front Grill Cream 5 384 007 Rear Panel 6 280 033 Control Panel Top Rear 7 920 443 Control Panel Decal Top On Off Fan 8 384 917 Fan Assembly Complete 9 945F SimpsonDurave...

Страница 48: ...ng Elbow 90 Degree Forged Valve Outlet End N S 904 606 Fitting Elbow 90 Degree Forged Valve Inlet End N S 904 658 Inlet Flex Line Gas SS Steel 24 inch N S 910 941 4 m m Valve Screw With Red O Ring N S...

Страница 49: ...Hampton H15U NG LP Direct Vent Freestanding Gas Stove 49 notes...

Страница 50: ...n Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crys...

Страница 51: ...wndrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack o...

Страница 52: ...ide the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the auth...

Страница 53: ...elow in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Produ...

Страница 54: ...54 Hampton H15U NG LP Direct Vent Freestanding Gas Stove warranty...

Страница 55: ...Hampton H15U NG LP Direct Vent Freestanding Gas Stove 55...

Страница 56: ...Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ______________________________________________________...

Отзывы: