background image

6

E33 FPI Direct Vent Gas Insert

IMPORTANT MESSAGE 

SAVE THESE 

INSTRUCTIONS

The FPI Gas Insert must be installed in accord-
ance with these instructions. Carefully read all 
the instructions in this manual fi rst.  Consult 
the building authority having jurisdiction to 
determine the need for a permit prior to starting 
the installation.

NOTE: 

 Failure to follow the instructions could 

cause a malfunction of the heater which could 
result in death, serious bodily injury, and/or 
property damage.  Failure to follow these 
instructions may also void your fi re insurance 
and/or warranty. 

FOR YOUR SAFETY

This appliance requires air for proper combustion. 
Always provide adequate combustion and 
ventilation air.  Follow instructions and 
information in CSA B149.1 (in Canada) or the 
National Fuel Gas Code ANS Z223.1/NFPA 
(in the USA), regarding requirements for 
combustion and ventilation air.

GAS PRESSURE 

TESTING

The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut off valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than
1/2 psig. (3.45 kPa).

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit 
must be disconnected.

Gas Input Capacity:

  

 

Natural Gas  38,000 Btu/h

 Propane 

35,500 

Btu/h

Min. Input:

 

Natural Gas  20,000 Btu/h

 Propane 

19,000 

Btu/h

Fuels: 

 Approved for use with both natural gas, 

and propane. Approved as is for use at 0' to 
4,500' (0-1370m).

Electrical:

            120V A.C. system.

Circulation Fan: 

 Variable speed, 127 CFM.

Log Set: 

              Ceramic fi bre, 8 per set.

Vent System:

       3" co-linear aluminum fl ex.

INSTALLATION

INSTALLATION INTO A 

SOLID FUEL BURNING 

FIREPLACE OR 

FACTORY BUILT 

FIREPLACE

The E33 Gas Inserts have been tested and 
approved to be vented into any masonry 
fireplace or approved solid fuel burning 
factory built fi replace that will allow the insert 
to physically fi t into the fi rebox. Refer to the 
"Minimum Fireplace Dimensions" section.

If the factory built fi replace* height is too low 
for your Insert, you may remove the smoke 
baffl e plate and damper from the factory 
built  fi replace as long as these items are 
saved and are reinstalled in the event that 
the Insert is removed. NOTE: Any alterations 
made to the listed solid fuel burning factory 
built  fi replace may void the listing of the 
fi replace. Cutting any sheet-metal parts of 
the fi replace, in which the gas fi replace insert 
is to be installed, is prohibited.

If the factory-built fi replace has no gas 
access hole(s) provided, an access hole of 
1.5" (37.5mm) or less may be drilled through 
the lower sides or bottom of the fi rebox in 
a proper workmanship like manner. This 
access hole must be plugged with non-
combustible insulation after the gas supply 
line has been installed. 

The  fi replace  and  fi replace chimney must 
be clean and in good working order and 
constructed of non-combustible materials 
and chimney cleanouts must fi t  properly. 
Refractory, glass doors, screen rails, screen 
mesh, and log grates can be removed 
from the fi replace before installing the gas 
fi replace insert. Smoke shelves, shields 
and baffl es may be removed if attached by 
mechanical fasteners. A tight connection 
between the gas fi replace insert fl ue collar 
and the fi replace chimney must be made.

*Check with your local inspector before 
commencing with this installation.

BEFORE YOU START

Safe installation and operation of this appliance 
requires common sense, however,  we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:

General Safety Information

1)

  The appliance installation must conform 

with local codes or in the absence of local 
codes, with CAN/CSA B149.1 (in Canada) 
or the National Fuel Gas Code ANSI Z223.1 
NFPA 54 in the U.S.A. This appliance should 
be installed by a qualifi ed gas fi tter technician 
only.

2)  Installation and repair should be done 

by a qualifi ed service person.  

3)  The appliance should be inspected 

before use and at least annually by 
a professional service person. More 
frequent cleaning may be required due 
to excessive lint from carpeting, bedding 
material, animal hair, etc.  It is imperative 
that control compartments, burners 
and circulating air passageways of the 
appliance be kept clean. 

4)

  See general construction and assembly 

instructions. This appliance may only be 
installed in a vented, noncombustible 
fi replace.

5)

  This appliance is Listed for bedroom 

 

installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.

6)

  Always connect this appliance to a vent 

system vent that is run (or routed) to the 
outside of the building envelope. Never vent  
to another room or inside a building. Make 
sure that the vent is properly sized and is 
of adequate height to provide the proper 
draft.  

7)

  Inspect the venting system annually for 

blockage and any signs of deterioration.   

8)

  Any glass removed for servicing must be 

replaced prior to operating the appliance.  

9)  WARNING: Failure to position the parts 

in accordance with the diagrams in 
this manual or failure to use only parts 
specifi cally approved with this appliance 
may result in property damage or 
personal injury.

10)

 To prevent  injury, do not allow anyone who 

is unfamiliar with the operation to use the 
fi replace.  

Installer must mechanically attach the supplied 
label to the inside of the fi rebox of the fi replace 
into which the gas fi replace insert is installed.

"

WARNING

: This fi replace has been converted 

for use with a gas fi replace insert only and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."

Содержание E33-LP1

Страница 1: ...tallation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do not touch any ele...

Страница 2: ...ch The E33 NG1 and E33 LP1 have been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many troub...

Страница 3: ...CO Detector for the State of Massachusetts only 5 INSTALLATION Important Message 6 For Your Safety 6 Gas Pressure Testing 6 Specifications 6 Installation Into A Solid Fuel Burning Fireplace or Factor...

Страница 4: ...local codes if any If none follow the National Fuel Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 This vented gas fireplace heater is not for use with air filters D...

Страница 5: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY...

Страница 6: ...been installed The fireplace and fireplace chimney must be clean and in good working order and constructed of non combustible materials and chimney cleanouts must fit properly Refractory glassdoors s...

Страница 7: ...rnia to cause cancer birth defects or other reproductive harm a Brick Panels b Log Installation c Faceplate Trim d Standard Flush Door e Flush Louvers f Full Screen Doors g Excalibur Surround h Excali...

Страница 8: ...Alcove side wall must have a min of 8 clearance on one side COMBUSTIBLE MANTEL CLEARANCES Because of the extreme heat this fireplace emits the mantel clear ances are critical Note Anon combustible man...

Страница 9: ...rough the chimney above the appliance Movetheapplianceintotheexact location where it is to be installed Ensure that the Insert is level In areas of consistently high winds we recommend using the Simps...

Страница 10: ...he pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconn...

Страница 11: ...ket 5 Place the top bracket onto the top edge of the top panel refer to Diagram 2 Diagram 2 6 Slide the top panel and bracket assembly carefully onto the baffle plate ensuring the panel is centered Ma...

Страница 12: ...do not force them into position to avoid chipping 3 Remove the grate by removing the two Phillips screws Slide the grate outwards to remove it from the unit refer to Diagram 1 Diagram 1 2 Remove the...

Страница 13: ...into position until it touches the locating tab see Diagram 6 7 Locating Tab 03 20 Locating Pin Diagram 6 Diagram 7 03 23 03 20 03 17 03 21 9 Place log 03 22 over log 03 23 and log 03 20 Ensure the pi...

Страница 14: ...4 lines up with the right pin of log 03 23 and the right pin of log 03 21 refer to Diagram 11 03 24 03 23 03 21 Locating Pins Diagram 11 12 Place log 03 19 over the left center of the grate Ensure the...

Страница 15: ...llation section in E33 Manual Ensure you slide the bottom log 03 17 off to the right hand side to avoid chipping 5 Remove burner by unscrewing the 2 screws 6 Pull off the pilot cap to expose the pilot...

Страница 16: ...cordance with the authority having jurisdiction If the information in these instruc tion is not followed exactly a fire explosion or production of car bon monoxide may result caus ing property damage...

Страница 17: ...anging the battery Installer Notice These instructions must be left with the appliance 41 Check for gas leaks with a proper soapy solution or leak detector 42 Check for proper spark between the ignito...

Страница 18: ...4 and do a trial fit to the unit Make any necessary adjustments and when it fits properly then tighten down the screws Diagram 3 7 Tuck the wires into the faceplate to keep them away from the insert...

Страница 19: ...ceplate as shown Fan Rheostat 3 Secure loose wires using wire clips along the back of the left side of the faceplate Ensure to run the wires away from the firebox as much as possible 4 Align the facep...

Страница 20: ...over top of the glass door push in the bottom of the door frame to secure in place NOTE To ensure the gap between the door frame and faceplate legs are equal approximately 1 2 on each side you may ne...

Страница 21: ...rthehinge Flip hinge over the Bottom Louver and secure using 3 screws Bottom Louver Hinge Location 1 The top louver is held in place by friction fit Refer to Diagram 1 Diagram 1 4 Install the Top Fram...

Страница 22: ...Doors by placing over top of the hinges on the faceplate Hold the door at a 45 degree angle to avoid scratching the faceplate 8 Close screen doors Hinge Screen Door 3 Hold the Faceplate Trim up again...

Страница 23: ...plit lock washer and then the nut and tighten DOUBLE DOOR OPTION Remove the handles by removing the nut andscrew Installthenewhandlesbyplacing theminpositionovertheholesonthedoor s Put the studs throu...

Страница 24: ...g plug for your protection against shock hazard and should be plugged directly into a properly groundedthree prongreceptacle Donotcutorremove the grounding prong from this plug Caution Ensure that the...

Страница 25: ...n the wall Switch the remote receiver to remote mode The remote control is now ready for operation OPTIONAL REMOTE CONTROL OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired follow...

Страница 26: ...disappear in a few minutes as the glass heats up DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this applia...

Страница 27: ...N This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burnertube s andlogsandismadeofad...

Страница 28: ...his condensation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place or with the door open 7 Donotusethi...

Страница 29: ...pliance with glass panels removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person Flush Glass Replacement Remove the flush door front refer to the S...

Страница 30: ...fan 15 Reverse above steps Sealfanaccesspanelusinghightemperature silicone sparingly 13 Pull Fan Assembly forward to disengage the fan clip on the rear wall Then lift the Fan Assembly up and pull thro...

Страница 31: ...19 Grommet for Power Cord 340 924 Flush Louvers Set Black Gold 340 922 Flush Louvers Set Black 340 926 Flush Louvers Set Black Steel 21 Top Flush Louver 23 Bottom Flush Louver 340 901 Brick Panel Set...

Страница 32: ...T Natural Gas Propane 59 Valve Tray 910 034 Pilot Assy 3 Flame Conv NG 66 910 038 Pilot Assy 3 Flame S I T NG 910 039 Pilot Assy 3 Flame S I T LP 67 904 690 Orifice 31 NG 904 641 Orifice 50 LP 936 170...

Страница 33: ...8 88 89 90 90 FULL SCREEN FRONT Part Description PARTS LIST 83 Top Frame 84 340 910 Full Screen Door Black 85 Full Screen Left Door 86 Full Screen Right Door 87 Bottom Frame 88 Screw 8 x 1 2 Self Tapp...

Страница 34: ...lack 94 Trim Side Right 95 Trim Top 96 Trim Side Left Assy 97 910 246 Burner ON OFF Switch 98 910 330 Fan Speed Control 120 V 99 Faceplate Filler 172 320 940 Hearth Trim 1 176 320 942 Hearth Trim 2 18...

Страница 35: ...AME Part Description 341 914 Contemporary Faceplate Door Frame 90 Complete Faceplate 91 Door Frame 92 Bottom Louver 93 Hinges 910 246 Burner ON OFF Switch 910 330 Fan Speed Control 120V 904 569 Fan Sp...

Страница 36: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 37: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 38: ..._______________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________...

Страница 39: ...portation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of...

Страница 40: ...__________ Printed in Canada FPI fireplace products are designed with reliability and simplicityinmind Inaddition ourinternalQualityAssurance Teamcarefullyinspectseachunitthoroughlybeforeitleaves our...

Отзывы: