Part No. 20862 Rev. G February 2015
- 18 -
Chilled Cabinets
Interior
cont.
CABINETS - CLEANING
Cleaning the
Base Cavity
The cabinet base is mounted on runners,
and can be pulled forwards to access the
base cavity.
Sweep out, or use a vacuum cleaner, to
remove any debris.
A Wet-and-Dry vacuum cleaner should be
used, since there is likely to be some water
in the bottom.
Fan Deck
The fan deck is not fixed, and can be lifted
up, unplugged and removed for cleaning.
Condensate
Pump Intake
Filter
Lift the lid off the condensate pump intake
filter and remove any debris.
The pump control switch is operated by a
magnet, mounted on a float. Be sure to fit
the float with the magnet against the lid,
when it is
replaced.
Condensate
Capacity
Warning
The condensate pump and boil off heater is only designed to handle cooling-coil
defrosting water that drains from the well during normal operation. The boil off
container has a capacity of two litres.
When cleaning, DO NOT fill the well with liquid, or attempt to hose it out. The
condensate pump only operates when the main switch is on, so the well will not
empty until the power is switched on again.
Cleaning
Materials
Steel trays, shelves, grills etc. should be cleaned with hot soapy water then
dried off with paper towel or dry cloth.
DO NOT use abrasive pads or cleaners as these may damage surfaces.
Warning:
Dishwasher detergent may damage anodised aluminium parts.
Continued on next page