IN
– M11C-B003/004/007
- 13 -
© Future Products Group
TROUBLE SHOOTING
FAULT
POSSIBLE CAUSE
REMEDY
Cabinet does not
operate/start
The mains isolating switch on
the wall, circuit breaker or fuses
are off at the power board
Turn isolating switch circuit
breaker or fuses on
The power switch on the cabinet
is OFF
Turn the power switch ON
The internal MCB has tripped off
or failed
Have wiring checked and
reset or replace breaker
The power switch is faulty
Have the switch replaced
Boil-off system has failed
See detailed instructions below
Refrigerated Cabinet does
not reach temperature
Ventilation grills are blocked
Vacuum or remove blockage
Product blocking air grill
Place product on shelves
Thermostat needs adjustment
Adjust refrigeration controller
Ambient temperature > 25
C
Adjust store air conditioning
Evaporator coil iced up
De-ice coil, check active
defrost parameters, replace
controller if found faulty
Condenser radiator blocked
Remove dust and debris
Refrigeration controller faulty
Replace controller
Temperature probe damaged
Replace temperature probe
Fans not operating
Have fans checked/replaced
HP pressure switch triggered
Manually reset switch
LP pressure switch triggered
Allow switch to auto reset.
If it
doesn’t reset, check for leaks
(Clear the alarm indication, by turning off the power to reset the controller)
Condensate Overflows
Condensate pump failed
Have the pump replaced
Pump filter blocked
Clean the filter
Pump water level switch faulty
Check/replace unit
Boil-off control module failed
Check/replace control module
Cabinet lights not working
Fluorescent tube failed
Replace fluorescent tube
There is a cabinet fault alarm
See additional information
below
The internal MCB has tripped off
or failed
Have wiring checked and
reset or replace breaker
Aluminium parts corroded
Caustic detergent damage
Order replacement parts
Service
Personnel Only
The table entries in
italics
indicate actions to be taken only by qualified Service
Personnel.