Part No.23747 Rev. F June 2017
- 26 -
Refrigerated Well GN Series
Refrigeration
cont.
GN SERIES REFRIGERATED WELL - SERVICING
Condenser
Radiator
For efficient refrigeration performance, the condenser
radiator must be kept clean. Failure to do this will lead
to a build-up of dust, and restricted airflow will prevent
the unit from working properly. The compressor may
overheat and the well temperature may rise. Be careful
not to bend or damage the soft aluminium fins when
vacuuming the radiator. If the fins are flattened, airflow
will be restricted and overheating will result.
Regular pre-filter cleaning and vacuuming will prevent a
build-up of dust and fluff, but three monthly service
checks, by a refrigeration engineer, are mandatory. These
should include cleaning the condenser radiator using
compressed air.
Temperature
Probes
There are two temperature probes on the cooling coil,
One is inserted between the fins and the other is in
free air.
Fan Deck
The fan deck can be disconnected and
removed from the well, when servicing the
fans.
Continued on next page