220V MODELS ONLY
(You cannot switch to 110 volt power)
STEP 1 - Wiring
All electrical equipment must be located 1.50 m or more from closest pool or spa waterline. Use the
green and yellow stranded wire for Control Panel grounding. Attach a #8 or #6 solid bond wire to
the bonding lug on the underside of the unit.
STEP 2 - Wire from the sub-panel - Your GALAXY 2000 Control Panel is shipped factory set to 220
VAC ONLY. The Control Panel will operate at either 50Hz or 60Hz line power. Ensure that the filter
pump AC voltage used matches the Control Panel voltage. Improper wiring will damage the Control
Panel, which is not covered under warranty. Connect AC power to the blue and brown wires using
wire nuts.
STEP 2 a - Control Panel Hook-up - Ensure that the main filter pump circuit breaker is set to OFF.
Connect AC from the LOA D SIDE of the external time clock, Compool/Jandy filter pump relay or
on/off switch to the GALAXY 2000 Control Panel so that it operates only while the filter pump
operates. For flexibility, ease of wiring and making connections, #14 gauge stranded wire (2.1m) is
recommended for interconnection between the external control system and the Control Panel.
Wiring diagrams are located on the Control Panel's backplate. Plug the cell and flow switch cords
into the bottom of the unit.
110V MODELS ONLY (You cannot switch to 220 volt power)
STEP 1 - Plug the GALAXY 2000 unit into a G.F.C.I. (Ground Fault Circuit Interrupter) protected
outlet or timer.
STEP 2 - Plug the 110V filter pump into the GALAXY 2000 unit AC outlet.
WARNING -This AC outlet is intended ONLY for the filter pump. DO NOT use for any other purpose.
Each GALAXY 2000 Automatic Sanitizing System consists of three (3) main components:
The CONTROL PANEL converts incoming AC power to a Low Voltage DC current which energizes
the Cell.
The CELL receives that Low Voltage DC current from the Control Panel, indicated by a flashing
green OK indicator, which initiates the electrolytic process and allows purifier to be produced.
This process converts salt (Sodium Chloride) to Sodium Hypochlorite which in turn purifies
your pool. This salt then reverts back to ordinary salt and the entire process is repeated.
The FLOW DETECTOR ensures adequate flow is present to produce purifier. Further, it protects
the Cell from damage caused by insufficient flow. If the flow rate drops below 57 LPM, the
Control Panel will display a single red flashing CHECK SYSTEM indicator and the OK indicator will
display dark.
BOTH MODELS
STEP 1 - Plug the cell cable into the cell and the other end into the 3 circuit connector located at
the bottom right side of the GALAXY 2000 unit. It matches only one type connector, and it's keyed.
You can't make a mistake.
STEP 2 - Plug the flow switch cable into the WHITE 2-circuit connector closest to the wall at the
bottom of the GALAXY 2000 unit. This input connector is keyed. See drawing top left page 17.
Control Panel Wiring