VDC-7/VDC-15 Long Range Video/Data/RC Transmission System
User Manual
©
2020 FOXTECH All Rights Reserved
22
13. Select Encryption: You can disable/enable the encryption. When enable this function, you can set your
private password. The password should in the range of 100000~999999. Devices
with different password do not link.
14. Select Working mode: There are two working mode of VDC-7/VDC-15——Point to Point mode and
Repeater mode. Choose the working mode you neededand click ‘Set’ button to complete setup. Click the
‘Get’ button to get current working mode. This function only needs to be set up
on the VDC-7/VDC-15 air unit. The ground unit can synchronize automatically. If you select Repeater mode,
you need to select the air unit whether it is TX or repeater.
How to use Assistant
1. Connect VDC-7/VDC-15 with Assistant
Assistant is a Windows software that configures VDC-7/VDC-15. Before configuration, please connect the
UART1 to computer via UART(TTL) to USB converter.
Select the right COM and baud rate. Click ‘open’ button.
2. Read current parameter
After step1, click ‘Read’ button. All current parameter will print on the information display. Because the
Working mode is only for air unit. The Working mode box will turn grey on ground unit configuration.