Foxtech EH640 30x Optical Zoom IR Thermal Camera

 User Manual

©

2020 FOXTECH All Rights Reserved

  

5

Interface description:

External interfaces on IDU/IDUS include:
Power cord :12-25v
4p network port: used to connect computer, video transmission module.
7p extension interface (including serial port, CAN bus interface): 

only deeply customized and development 

customer, or the customer using T1, M2 flight control need to use this interface.

Video Transmission System

Ground Station Software

Extension Module

Brief functional description

R2S  is  the  latest  network  version  video,  data  link.  with  two  video  input/out  interface,  one  serial  port, 
maximum transmission distance of 15 km.

Mobile phone app, PC brief functional description

Refer to corresponding software usage instructions.

SBUS module Introduction

To meet the usage of different users, toway provides sbus transfer mode. Through the sbus module, the 
user can use the SBUS remote control to control the Tuowei whole pod. SBUS module usage instructions 
detailed, SBUS usage instructions.

Mission management module
IRIS

IRISI1 uses industrial high performance CPU, equipped with 4G communication module, external expansion 
of 3 channels of CAN bus interface ,2 channels of serial port ,3 channels of network port, convenient for all 
types of flight control, mission equipment access and management. The task management unit realizes the 
highly self-automation and intelligence of the UAV industry task through the cooperative management of the 
flight control and the task equipment.
It can realize the display and control functions such as remote viewing of pod image, remote control of pod, 
remote transmission of flight control information through 4G communication mode.
IRIS embedded Mavlink protocol, support PIX and other flight control, other flight control can use serial 
transmission.
Independently developed SaaS-level services, with task management unit, can achieve UAV remote task 
planning, real-time monitoring and other functions, image transmission delay is only 100ms.
You can use the traditional microwave point-to-point video transmission while using the IRIS 4G video 
transmission function, double guarantee to ensure the link security.

Содержание EH640

Страница 1: ...User Manual V1 0 Foxtech EH640 30x Optical Zoom IR Thermal Camera with 3 axis Gimbal 2020 03...

Страница 2: ...Once used it is deemed to be an endorsement and acceptance of the entire contents of this statement Please read the instruction manual carefully and strictly follow the requirements of this manual to...

Страница 3: ...las Pod IDU IDUS Video Transmission System Ground Station Software Extension Module Installation with notes Hardware Installation Software Installation and Configuration Installation and setup methods...

Страница 4: ...sassemble gateway damping Datalink 5 8G videolink 2km R2S 15km video data link R2PRO integrated video datalink IRIS 4G video datalink Software GCS Android Windows Custom QGC Android Windows TOPGUN sof...

Страница 5: ...system diagram wiring instructions wire sequence definition SBUS professional pod wiring diagram 4P network port 7p expansion port Power supply 12 25V Serial port 1 Serial port 2 The receiver needs se...

Страница 6: ...iring notices Pod IDU IDUS Brief functional description supported pod type etc The pod system is divided into two levels professional load lightweight load Adapt to different levels of multi rotor dro...

Страница 7: ...ns detailed SBUS usage instructions Mission management module IRIS IRISI1 uses industrial high performance CPU equipped with 4G communication module external expansion of 3 channels of CAN bus interfa...

Страница 8: ...y connected no loosening no breakage of the cable Please keep a certain activity space redundancy for power cord network cable serial port C IDU and videolink sky end Power Supply IDU IDUS R2S with sk...

Страница 9: ...modification take change 42 segment to 1 segment as an example 1 pod electrified and connected the pod to the computer through the wire the pod works normally after about 15 seconds the computer recog...

Страница 10: ...ptical Zoom IR Thermal Camera User Manual 2020 FOXTECH All Rights Reserved 8 4 Camera IP modification Open any browser enter 192 168 42 108 After entering the following interface username password are...

Страница 11: ...hen the following password modification interface appears click cancel After entering the setup interface click Settings Network Settings General Settings Change the IP address and default gateway 42...

Страница 12: ...ettings the equipment used shall prevail Pod RTSP Common Address Main stream rtsp admin admin ip 554 cam realmonito Channel 1 subtype 0 Secondary stream 1 rtsp admin admin ip 554 cam realmonito Channe...

Страница 13: ...l Property 4 TCP IPv4 General Settings Use the following IP address Different data link settings are different see the corresponding data link user manual for details Confirm 5 8G Datalink also option...

Страница 14: ...digital link CAN transfer When operating in an environment with large pre and post flight temperature differences e g winter aircraft moving from indoors to outside Calibration is recommended before...

Страница 15: ...s Reserved 13 Operating Pods gcs support remote real time download of camera side video photos 1 Operational steps view download interface as shown below can download video MP4 style photo jpg offline...

Страница 16: ...ve the damage to break the circuit Software setup check Make sure the computer network is set correctly and the computer turns off the wifi when connecting the datalink The computer is not connected t...

Отзывы: