FoxGate S9816-GS8 Скачать руководство пользователя страница 4

 

S98XX  series  switch  provide  AC/DC  power  redundancy.  S9816-GS8  and 

S9816-GS8X2 can be deployed with 220V AC power input, -48V DC power input or 

220V  AC  power/-48V  DC  power  input  simultaneously.  S9820-GS4M2T2  and 

S9844-GS4M2T2 can be deployed with 220V AC power input, 12V DC power input or 

220V AC power/12V DC power input simultaneously. 

 

Support 10Gb Ethernet 

10Gb  Ethernet  which  adopts  full-duplex  technology  instead  of  low-speed, 

half-duplex  CSMA/CD  protocol,  is  a  big  leap  in  the  evolution  of  Ethernet.  10Gb 

Ethernet  can  be  deployed  in  star  or  ring  topologies.  With  10Gb  Ethernet,  S98XX 

series switch provide broad bandwidth and powerful processing capacity. It is suitable 

for metropolitan networks and wide area networks. Using S98XX series switch, users 

can simplify network structures and reduce cost of network construction.       

 

Networking Protocols 

S98XX  series  switch  support  802.1d/w/s,  802.1Q,  802.1p,  802.3ad,  802.3x, 

GVRP,  DHCP  and  SNTP  etc.  The  switches  also  support  comprehensively  the 

multicast protocols such as IGMP, DVMRP and PIM. Moreover, S98XX series switch 

support RIPv1/2, OSPF and IPv6. All these protocols supported enable S98XX series 

switch to meet the requirements of complex network constructions.   

 

ACL 

S98XX  series  switch  support  comprehensively  ACL  policies.  The  traffic  can  be 

classified by source/destination IP addresses, source/destination MAC addresses, IP 

protocols, TCP/UDP, IP precedence, time ranges and ToS. And various policies can 

be conducted to forward the traffic. By implementing ACL policies, users can filter the 

virus  packets  such  as  “Worm.Blaster”,  “Worm.Sasser”  and  “Red  Code”  etc.  S98XX 

series switch also support  IEEE802.1x port based access authentication, which can 

be deployed with RADIUS, to ensure the port level security and block illegal users.   

 

QoS 

S98XX  series  switch  fully  support  DiffServ  Module.  Users  can  specify  a  queue 

bandwidth on each port. WRR/SP/SWRR scheduling is also supported. S98XX series 

support  the  port  security.  Users  can  deploy  trusted  CoS,  DSCP, IP  precedence  and 

port priority. User can also modify packets‟ DSCP and COS values. The traffic can be 

classified by port, VLAN, DSCP, IP precedence and ACL table. User can also modify 

packets‟ DSCP and IP precedence values. Users can specify different bandwidths for 

voice/data/video to customize different qualities of service.   

 

3D-SMP Ready   

S98XX  series  are  up  to  the  mustard  of  Self-defending  security  region 

management  strategy  according  to  FoxGate.  It  is  supported  interaction  with  some 

security  system  such  as  firewall,  IDS,  etc.  It  can  defense  the  virus  and  aggress 

effectively from the  extranet and internet. Thus enhance the security and stability of 

Содержание S9816-GS8

Страница 1: ...l Port Description 16 1 5 6 Back Panel Port Description 16 CHAPTER 2 HARDWARE INSTALLATION 18 2 1 INSTALLATION NOTICE 18 2 1 1 Environmental Requirements 18 2 1 2 Installation Notice 21 2 1 3 Security...

Страница 2: ...Introduction 1 1 Product Brief S98XX series switch include six models S9816 GS8 Figure 1 1 S9816 GS8 Switch S9816 GS8X2 Figure 1 2 S9816 GS8X2 Switch S9820 GS4M2T2 Figure 1 3 S9820 GS4M2T2 Switch S98...

Страница 3: ...xibility S98XX series switch with advanced intelligent and secure features can serve ideally as distribution layer switches for campus networks enterprise networks and IP metropolitan networks as well...

Страница 4: ...eries switch support comprehensively ACL policies The traffic can be classified by source destination IP addresses source destination MAC addresses IP protocols TCP UDP IP precedence time ranges and T...

Страница 5: ...155Mpps IPv6 Packet Forwarding Speed 130Mpps 130Mpps VLAN Item 4K 4K Layer 2 Protocol Specifications IEEE802 3 10Base T IEEE802 3u 100Base TX IEEE802 3z 1000BASE X IEEE802 3ab 1000Base T IEEE802 3ae...

Страница 6: ...iority Mark Remark ACL Carry out by hardware completely have no effect for forwarding performance Support Standard ACL and Extended ACL Support Dynamic ACL and egress ACL ACL X Support to change secur...

Страница 7: ...pport IPv4 IPv6 over RADIUS Configure network and management function Support IPv4 IPv6 syslog Support the unite for IPv4 IPv6 HTTP and SSL Support the user IP security inspection for IPv4 IPv6 SNMP S...

Страница 8: ...Exchange capacity 368 Gbps 416Gbps Packet Forwarding Speed 274Mpps 309Mpps IPv6 Packet Forwarding Speed 230Mpps 260Mpps VLAN Item 4K 4K Layer 2 Protocol Specification s IEEE802 3 10Base T IEEE802 3u 1...

Страница 9: ...k Support Traffic Shaping Support priority Mark Remark ACL Carry out by hardware completely have no effect for forwarding performance Support Standard ACL and Extended ACL Support Dynamic ACL and egre...

Страница 10: ...rt IPv4 IPv6 over RADIUS Configure network and management function Support IPv4 IPv6 syslog Support the unite for IPv4 IPv6 HTTP and SSL Support the user IP security inspection for IPv4 IPv6 SNMP Supp...

Страница 11: ...d management 1 4 Physical Specifications Management Port S9816 GS8 26 1 Mini USB serial console port S9820 GS4M2T2 52T 1 RJ 45 serial console port AC DC Power Input S9816 GS8 26 AC 90 264VAC 47 63Hz D...

Страница 12: ...b Combo ports 8 RJ 45 and 8 SFP ports 2 10Gb XFP ports 1 Console port and 70 LEDs The front panel of S9816 GS8X2 is shown below Figure 1 6 Front Panel of S9816 GS8X2 S9820 GS4M2T2 has 20 1000Mb RJ 45...

Страница 13: ...slots and 2 10Gb stack slots Figure 1 10 Back Panel of S9820 GS4M2T2 and S9844 GS4M2T2 1 5 3 DC Power Input S98XX supports AC DC power redundancy The figure below shows the DC Power Input of S9816 GS8...

Страница 14: ...em is operating normally On Green blink at 8 Hz System is loading On Red blink at 8 Hz System is malfunctioning RJ 45 Port Indicator Status Indicator On the left On Green RJ 45 port is connected Off R...

Страница 15: ...unctioning RPC On Green Redundancy power unit is charging ON Yellow Redundancy power unit is malfunctioning Off Redundancy power unit is off Stack Master ON Green Switch is the master unit of the stac...

Страница 16: ...TP 100 m SFP SFP 2MM 850nm 0 5LC 1000Base SFP 850nm MMF 500m SFPd 2SM 1310nm 10LC 1000Base SFP 1310nm SMF 10km SFP 2SM 1310nm 20LC 1310nm lightwave 9 125um single mode fiber 20km SFP 2SM 1310nm 40LC 9...

Страница 17: ...her switch applying the intercommunication among the stacks In the close loop stack an extra stack line link the top and bottom switch to form a close loop structure The close loop stack supports one...

Страница 18: ...ncidence Keep the switch away from heat sources and strong electromagnetic interference sources The switch must be mounted to a standard 19 rack or placed on a clean level desktop 2 1 1 1 Dust and Par...

Страница 19: ...n materials thus reducing the switch s working lifespan In the hot summer it is recommended to use air conditioners to cool down the site And the cold winter it is recommenced to use heaters The recom...

Страница 20: ...proper temperature and humidity Always wear an ESD wrist strap and antistatic uniform when in contact with circuit boards 2 1 1 5 Anti interference All sources of interference whether from the device...

Страница 21: ...ear antistatic uniform and ESD wrist straps Users should use standard cables and connecters After the installation users should clean the site Before powering on the switch users should ensure the swi...

Страница 22: ...n proper first aid treatment according to the injury state and seek help from the Medical Emergency using various ways 2 2 Installation Preparation 2 2 1 Verify the Package Contents Please unpack the...

Страница 23: ...he rack Figure 2 4 S9844 GS4M2T2 Install sketch map on the rack Please mount S98XX series on the 19 rack as below 1 Attach the 2 brackets on the S98XX series with screws provided in the accessory kit...

Страница 24: ...nsole S98XX series provides a Mini USB serial console port Figure 2 5 Connecting Console to S98XX The connection procedure is listed below 1 Find the console cable provided in the accessory kit Attach...

Страница 25: ...ist strap or antistatic gloves Step 2 Insert the XFP transceiver to the guide rail inside the 10 Gb line card Do not to put the XFP transceiver up side down Step 3 Push the XFP transceiver along the g...

Страница 26: ...Check the fiber port status indicator a lighted LED indicates that the link has been established otherwise the link is not ready and should be examined Caution Please verify the sign above the port to...

Страница 27: ...ont panel of the switch The corresponding power indicator should light S98XX is self adjustable for the input voltage As soon as the input voltage is in the range printed on the switch surface the swi...

Отзывы: