Terrier T200 LSA Flight Manual Rev No.: 1.0 15 April 2008
Page 20 of 31
8.5 Fire
8.6 Fire during Start on Ground
1
Cranking
CONTINUE to get a start that would suck the flames and
accumulated fuel through the carburettor and into the engine.
If engine starts,
2
Power
2500 RPM
3
Fuel
OFF & allow engine to empty carburettor
4
Engine
Inspect for damage
If engine fails to start,
5
Cranking
CONTINUE in an effort to obtain a start. If no start in 15 seconds :
Shut off fuel & continue to crank for another 15 seconds.
6
Engine
SECURE.
A Second Ignition Switch
OFF
B Master Switch
OFF
C Fuel Shutoff Valves
Both OFF
7
Fire
Extinguish using fire extinguisher, wool blanket, or dirt.
8
Fire Damage
Have authorised people inspect, repair damage or replace
damaged components or wiring before conducting another flight.
8.7 Engine Fire in Flight
1
Throttle
CLOSED
2
Fuel Shutoff Valves
Both OFF
3
Ignition Switches
OFF
4
Master Switch
OFF
5
Cabin Air
CLOSE
6
Airspeed
75 knots (if fire is not extinguished, increase glide speed to find an
airspeed which will provide an incombustible mixture).
7
Forced Landing
Execute (as described in Emergency Landing Without Engine
Power).
8.8 Electrical Fire in Flight
1
Master Switch
OFF
2
All Other Switches
OFF
3
Vents/cabin air (*)
OPEN THE CABIN DOOR
If fire appears out and electrical power is necessary for continuance of flight:
4
Master Switch
ON
5
Second Ignition Switch
ON
6
Fuses
CHECK for faulty circuit,
DO NOT
reset or replace.
7
Radio/Electrical Switches
ON one at a time, with delay after each switch until short
circuit is localised.
8
Land as soon as possible to inspect for damage
8.9 Cabin Fire
1
Master Switch
OFF
2
Vents/Cabin Air (*) / Door
OFF
3
Land as soon as possible to inspect for damage.