Foto Walser walimex pro VC-1000 PLUS Скачать руководство пользователя страница 12

 

 

 

 

 

Locking Lever 

Locking Knurl 

Tripod Mount 

1.

 

Loose locking lever. 

2.

 

Open locking knurl. 

3.

 

Mount the device on the tripod. 

4.

 

Tighten locking knurl. 

5.

 

Close locking lever. 

12.

 

Mount reflex umbrella (optional) 

 
Just use reflex umbrellas with a rod diameter of 8-10mm 

 

 

 

Tripod Mount 

Locking Knurl 

 

 

 

 

6.

 

Let the device cool down. 

 WARNING!

 Danger of burning on reflector, modeling lamp and flash 

tube. Please cool down approx. 30 minutes. 

7.

 

Open locking knurl. 

8.

 

Insert the rod of reflex umbrella through the opening in the reflector into 
the fixture as far as it will go.  

9.

 

Tighten locking knurl 

ADVICE: Don´t tighten the locking knurl too tight as to avoid damages on 
the reflex umbrella. 

13.

 

Switch on and off of modeling lamp 

1.

 

Switch on device. 
See 

Switch the device on and off

2.

 

Switch on modeling lamp: 
Press control OUTPUT POWER once. 

 

The modeling lamp switches on. 

 

The signal MODEL 

lights up.  

3.

 

Switch off modeling lamp: 
Press push-button OUTPUT POWER twice. 

 

The modeling lamp goes out.  

 

The signal MODEL 

 goes out. 

ADVICE: If you don´t switch off the modeling lamp before switching off the 
device, the modeling lamp will light up automatically, when switching on the 
device again. 

 

 

22 

21 

Содержание walimex pro VC-1000 PLUS

Страница 1: ...Gewerbering 26 86666 Burgheim Tel 49 84 32 9489 0 Fax 49 84 32 9489 8333 eMail info foto walser de www foto walser de Copy of Instruction Manual Studio Flash Series VC 200 PLUS to VC 1000 PLUS...

Страница 2: ...ash output 17 10 4 Switch the audio button on and off 18 10 5 Prepare and adjust flash trigger 19 Prepare flash trigger through camera 19 Prepare flash trigger through remote receiver optional 19 Swit...

Страница 3: ...This marking mean that your device meets the safety requirements of all relevant European Directives This marking mean that your device should be disposed in the local disposal points 1 2 Markings in...

Страница 4: ...n melt thoroughly This could lead to fire Please just use the original cables which are included in delivery They are aligned for your device and guarantee the necessary safety for you and your device...

Страница 5: ...ooling down Please cool down your device approx 30 minutes before starting any mounting or maintenance arrangements WARNING Danger of cutting and splitting through breaking modeling lamp and breaking...

Страница 6: ...is activated Modeling Lamp is activated 4 3 Quick start guide ADVICE The detailed instruction for the following operations can be found in the respective chapters in this instruction manual Keep the s...

Страница 7: ...nd listen for the cap to snap into place Release the unlocking lever Stick the safety cap onto the unlocking lever 6 Mount and demount reflector WARNING Posterior danger of bursting of flash tube Make...

Страница 8: ...nd flash tube Please let the device cool down for approx 30 minutes 4 Screw in modeling lamp When the protection cap is mounted Demount protection cap See Demount and mount protection cap Screw the mo...

Страница 9: ...as switched on when the device was switched off The function Photo Cell SLAVE lights up if photo cell or pre flash suppression were switched on when the device was switched off 3 Switch off device Set...

Страница 10: ...m flash output You can adjust the modeling lamp via 50 values Switch on device See Switch the device on and off 5 Press control OUTPUT POWER twice 6 The modeling lamp switches on The signal MODEL ligh...

Страница 11: ...tch on device See Switch the device on and off 2 Switch on photo cell Press push button SLAVE The signal SLAVE 1 is shown in the display 3 Switch off photo cell Press push button SLAVE until the signa...

Страница 12: ...the opening in the reflector into the fixture as far as it will go 9 Tighten locking knurl ADVICE Don t tighten the locking knurl too tight as to avoid damages on the reflex umbrella 13 Switch on and...

Страница 13: ...minutes Do not flash over 8 shots per minute for over 60 minutes In the above mentioned cases let the device cool down for at least 15 minutes o Don t switch off the device during the 15 minutes cool...

Страница 14: ...e device immediately Contact the Foto Walser service department Problem with power output Switch off the device for approx 30 minutes Danger of overloading Internal voltage inside the flash is too hig...

Страница 15: ...immediately ADVICE If you don t switch off the main switch within 0 5 seconds the device will charge anew Unplug power cord 2 Let the device cool down WARNING Danger of burning on reflector modeling...

Страница 16: ...use Holder 4 Pull out the fuse holder with your hands completely out of ft helot 5 Take out the old micro fuse 6 Take the new micro fuse out of the spare slot and slide it in the center of the holder...

Страница 17: ...PLUS VC 1000 PLUS Flash Output 200 W 300 W 400 W 600 W 800 W 1000 W Guide Number 2m ISO 100 55 65 75 85 95 105 Output Full tos 1 32 Recycling Time 0 8 1 8 s 1 2 s 1 2 2 s 2 3 s 2 5 5 s 2 6 6 s Flash...

Страница 18: ...uppression for 1 pre flash Switch off of pre flash suppression for 2 pre flashes C Push button TEST Triggers a test flash D Push button AUDIO Switches the acoustic beeper button on E Control OUTPUT PO...

Отзывы: