32
ROOM TEMPERATURE SETTING
With the unit in normal operating mode, the only active keys are “ON/OFF” (10) and “LAMP” (11). The latter is always
operative except when in programming mode.
Room temperature programming:
- Press key (10) to turn ON unit. The actual room temperature will be shown on the display (5). In this condition the
unit is ready for programming. It is necessary therefore to set the required room temperature bearing in mind the
limits of the range which the unit is able to operate.
- Press the SET key (6) (the yellow LED will light). The last set temperature will be displayed on the display screen
(5)
which shows the set value.
- Press the SET key (6), the yellowLED will light for one second and the display (5) will start flashing a few seconds
later, indicating the set temperature. If you wish to change the setting, use the following keys:
(8) to raise set temperature
(7) to lower set temperature
Once the required setting is displayed,
press the SET key (6) to confirm.
The unit is now fully operational and no other programming is required. The refrigerating cycle is fully automatic according
to factory-set parameters, that can eventually be modified by authorised personnel only.
Minimum Temp
Maximum Temp
Recommended Temp
“H” Range
- 5 °C
+ 10 °C
General Purpose
+ 3°C
Chilled
+ 1°C
Fresh Meat
- 2°C
“L” Range
-25 °C
- 15 °C
- 21°C
5) DISPLAY
When the machine is not in operation, the label “OFF” and the cell temperature are intermittently displayed
one after the other on the digital display. When the machine is in operation, during the normal working cycle,
the display indicates the room temperature. Parameters being set will be displayed during programming.
A “Fault Code” will be displayed during an alarm mode.
6) “SET” KEY -
Permits entry of room temperature requirements.
7) “DOWN” KEY -
Key to decrease data values.
8) “MAN.DEF./UP” KEY -
Key to increase data values
Press for 8 seconds at least to initiate manual defrost as well.
9) KEY “T.A.A.” -
Key to mute audible alarm
This alarm is not fitted as standard to the unit but can be added by the client. To connect use the free terminals
1 & 2 (volt free) on the internal electronic panel. Terminal 2 should have a live feed brought to it.
10) “ON/OFF” KEY -
Main switch
11) “LAMP” KEY
- Push to turn room lamp ON/OFF. A red LED lights when lamp is ON.
Содержание Solo Plus
Страница 1: ...S e r v i c e M a n u a l Solo Plus Units 2001...
Страница 2: ......
Страница 7: ...5...
Страница 8: ...6...
Страница 9: ...7...
Страница 24: ...22...
Страница 29: ...27 SOLO PLUS Service Manual...