Foster Solo Plus Скачать руководство пользователя страница 1

S

e

r

v

ic

e

 M

a

n

u

a

l

Solo Plus 

Units 2001

Содержание Solo Plus

Страница 1: ...S e r v i c e M a n u a l Solo Plus Units 2001...

Страница 2: ......

Страница 3: ...P 2 H LC 620 x 719 x 357 545 x 150 x 332 545 x 332 550 x 337 SP 3 H LC 820 x 809 x 390 745 x 150 x 332 745 x 332 750 x 337 SP 4 HC 820 x 809 x 390 745 x 150 x 332 745 x 332 750 x 337 SP 4 LC 820 x 929...

Страница 4: ...9 5 1800 400 3 50 5 9 2200 Hot Gas Auto 100 135 Foster Nom HP Cut Out HP Cut In Suction Valve Noise Heat Rejected RoomVent 32 C Ambient 43 C Ambient Air Air Vol Electrical Nominal Defrost Condensate N...

Страница 5: ...housing assembly releasing it from Assembly the 4 spring clips located in each corner it may be necessary to separate the fan housing assembly from the main body using a at blade screwdriver and gentl...

Страница 6: ...will turn ON and display the room temperature During programming mode the various parameters will be displayed and during alarm mode an alarm code will be displayed 6 SET ESC KEY Pressed for 3 second...

Страница 7: ...5...

Страница 8: ...6...

Страница 9: ...7...

Страница 10: ...LED are activated If more than ten trips occur during a 1 hour period then the unit will shut down automatically The remote relay will be activated and the label ERR will ash on the display alternatin...

Страница 11: ...le causes are Dirty condenser Condenser fan not running Front cover not tted Obstructed condenser air inlet TROUBLE SHOOTING 1 Compressor stops There is an internal over temperature device Klixon that...

Страница 12: ...frost type selection Number 0 to 3 2 2 0 Timed defrost 1 Electric defrost 2 hot gas 3 Off cycle dt Drain down time Minutes 0 to 250 2 2 dSt Defrost termination temperature C 1 50 to 150 15 15 Evaporat...

Страница 13: ...Remove the front panel of the unit and connect the cables to the terminal box as per the diagrams in g 1 2 3 and 4 11 Single Phase Unit L1 Brown N Blue PE yellow green BR BLYG L 1 L 1 N N PE Mains Su...

Страница 14: ...OTE LA refers to Low Ambient Models FOSTER CODE Internal fuse Wiring diagram SP101HW 16 A J1018 SP201HW 16 A J1018 SP301HW 20 A J1018 SP401HW 25 A J1018 SP501HW No fuses J2020 SP601HW No fuses J2019 S...

Страница 15: ...CONTROL CAB AUXILIARY FUSE ROOM LIGHT FUSE VOLTAGE REGULATOR 13 BA BC BS BVR BVRS E E1 M1 EP ER1 ER2 ES F13 F1 F1E FL F20 FM EMERGENCY STAT ALARM CONTACTOR DEFROST CONTACTOR COMPRESSOR MOTOR Nr 1 DOOR...

Страница 16: ...14 SUPPLY 400V 3N 50Hz Colour Code MA BROWN BL BLUE GV GREEN YELLOW NE BLACK Drawing No Sheet No J2020 1 of 1 Drawn By Approved Date Title SP501HW FOSTER REFRIGERATOR A Division of ITW Ltd...

Страница 17: ...LY 230 220V 1N 50Hz Colour Code MA BROWN BL BLUE GV GREEN YELLOW NE BLACK Drawing No Sheet No J1018 1 of 1 Drawn By Approved Date Title SP101LW SP101HW SP201HW SP301HW FOSTER REFRIGERATOR A Division o...

Страница 18: ...SUPPLY 400V 3N 50Hz Colour Code MA BROWN BL BLUE GV GREEN YELLOW NE BLACK Drawing No Sheet No J2019 1 of 1 Drawn By Approved Date Title SP201LW SP301LW SP601HW FOSTER REFRIGERATOR A Division of ITW L...

Страница 19: ...e coldroom 2 Air inlet and outlet to the evaporator located inside the coldroom 3 Electrical control panel located in the condensing unit enclosure 4 Wall mounted control panel A B C D E F G H I L M X...

Страница 20: ...6 3600 28 6 2300 400 3 50 5 1 2100 Hot Gas Auto 93 139 Foster Nom HP Cut Out HP Cut In Suction Valve Noise Heat Rejected RoomVent 32 C Ambient 43 C Ambient Air Air Vol Electrical Nominal Defrost Conde...

Страница 21: ...ed indicating the statues of the unit By pressing the ON OFF key for 3 seconds the unit is turned on with the room temperature displayed In the programming mode the parameters are displayed and if an...

Страница 22: ...UP DEFROST key till it displays 22 The rst parameter to be changed will be displayed Press the UP DEFROST key or the DOWN INTERIOR LIGHT key to scroll through the parameters Press the SET key to disp...

Страница 23: ...you reach the new value Press the SET key to con rm the value Repeat the operation to modify the required parameters To memorise the new values and exit the parameters press the ENTER key NOTE If you...

Страница 24: ...22...

Страница 25: ...will be displayed alternately Possible cause To frequent door openings The product load in the room exceeds the room capacity The temperature of the product stored in the room is too high Refrigerati...

Страница 26: ...e device Klixon that stops the compressor each time the admissible temperature of the motor windings is exceeded Possible causes are Insuf cient ventilation to the compressor Mains voltage anomaly Fau...

Страница 27: ...Colour Code MA BROWN BL BLUE GV GREEN YELLOW NE BLACK Drawing No Sheet No 81802LSB 1 of 1 Drawn By Approved Date Title SP3LC SP4LC SP4HC SP5HC FOSTER REFRIGERATOR A Division of ITW Ltd 25...

Страница 28: ...our Code MA BROWN BL BLUE GV GREEN YELLOW NE BLACK Drawing No Sheet No 81800LSB 1 of 1 Drawn By Approved Date Title SP1C SP1HC SPE SP2HC SP2LC FOSTER REFRIGERATOR A Division of ITW Ltd SP3HC SP3HC SPE...

Страница 29: ...27 SOLO PLUS Service Manual...

Страница 30: ...x 300 725 x 305 SP 4 LW 754 x 840 x 400 720 x 580 x 470 720 x 470 725 x 475 SP 5 H LW 754 x 840 x 400 720 x 580 x 470 720 x 470 725 x 475 SP 1 HC 620 x 719 x 357 545 x 150 x 332 545 x 332 550 x 337 SP...

Страница 31: ...uts Outputs 34 suitable protection must be provided Probe Resistance Values 34 Electrical Connections 35 Fuses 36 Table 1 Storage Conditions C Unit Type Refrigerator Meat Freezer Controller Fault Find...

Страница 32: ...2 28 23 3 61 1400 1550 11 1300 7 7 2300 400 3 50 4 8 2100 HG Auto 106 151 SP 5LW R 404a 1300 3 28 23 3 62 3600 1500 2000 17 1650 11 7 2300 400 3 50 4 1700 HG Auto 112 157 SP 1HC R 404a 570 0 625 59 2...

Страница 33: ...it from the 2 spring clips located at the top Evaporator Remove the 4 xing screws from the fan plate and lower allowing access to the evaporator fan Assembly motor and the evaporator assembly CONTROLL...

Страница 34: ...is required The refrigerating cycle is fully automatic according to factory set parameters that can eventually be modi ed by authorised personnel only Minimum Temp Maximum Temp Recommended Temp H Rang...

Страница 35: ...ress the key to display the value connected to the parameter 2C Modify the value pressing and until you reach the required one 2D Press the key to con rm temporarily the new value and return to the di...

Страница 36: ...9 to 19 9 0 No 1 YES rd REGULATION DELTA It de nes the temperature differential used in the temperature set point r1 MINIMUM SET ALLOWED De nes the lower value when tuning the set point of the device...

Страница 37: ...ode not the operation mode it was in before the alarm If the compressor is OFF a minimum OFF time is inserted if it is ON a minimum On time is inserted If c4 0 the compressor is always OFF if c4 100 t...

Страница 38: ...e temperature to exit the alarm range during and after defrost It also de nes the time to inhibit the temperature alarm after door is closed if the door switch is active d9 FORCE DEFROST START It allo...

Страница 39: ...ans always ON except for parameters F2 F3 Fd 1 fans controlled by a speci c fan regulator and by parameter Fd post dripping stop 2 fans controlled by the overall fan regulator and by a parameter Fd Th...

Страница 40: ...automatically reset EA EB EE ERROR IN DATA COLLECTION CONTROL RESET To restore correct operation reset the default parameters disconnect the machine from the mains supply hold down key and connect to...

Страница 41: ...1 d1 ore 0 199 4 4 dt C F 40 199 15 15 dP min 1 199 20 20 d4 ag 0 1 0 0 d5 min 0 199 0 0 d6 ag 0 1 0 0 dd min 0 15 2 2 d8 ore 0 15 1 1 d9 ag 0 1 0 0 d C F dC ag 0 1 0 0 A0 C F 0 1 20 2 2 AL C F 0 199...

Страница 42: ...Relay output switching single phase mains supply to the internal light if tted Door Frame Heater Direct single phase mains supply to the door frame heater if tted External Alarm Relay output switching...

Страница 43: ...ght cable which exits from the top of the evaporator housing If an independent light switch is used the light cable from the evaporator housing should not be used This cable must be insulated and secu...

Страница 44: ...16 1 5x20 F 6 CARD FUSE Power fuse Auxiliary fuse LIST OF FUSES POWER CURRENT FUSE This is a fuse tted in the line INTERNAL FUSES We mean those fuses tted in the control panel Above list shows quanti...

Страница 45: ...other Alarm relay activated Causes The sensor is not connected faulty Solution Replace sensor HIGH PRESSURE ALARM SP 5H SP 4L SP L5 only The label HH and the room temperature are intermittently displ...

Страница 46: ...8 During emergency period defrost cycle is not operating it is therefore advisable to reduce door openings to a minimum 9 When installing a new control panel remove all connections stated in items 3 a...

Страница 47: ...800L 1 of 1 Drawn By Approved Date Sonchl Martinelli 04 12 1997 Rev No Date Approved HVC Condenser Fan Motor H22 Internal Light HVE Evaporator Fan Motor MP Door Switch if tted M1 Compressor BS Defrost...

Страница 48: ...Approved Date Sonchl Martinelli 81801L Rev No Date Approved HVC Condenser Fan Motor K1 Compressor Contactor BS Defrost Probe HVE Evaporator Fan Motor H22 Internal Light BA Air Probe M1 Compressor EP D...

Страница 49: ...te Sonchl Martinelli 04 12 1997 Rev No Date Approved HVC Condenser Fan Motor K1 Compressor Contactor PHX High Pressure Switch HVE Evaporator Fan Motor H22 Internal Light BS Defrost Probe M1 Compressor...

Страница 50: ...800M 1 of 1 Drawn By Approved Date Sonchl Martinelli 03 12 1997 Rev No Date Approved HVC Condenser Fan Motor H22 Internal Light HVE Evaporator Fan Motor MP Door Switch if tted M1 Compressor BS Defrost...

Страница 51: ...y Approved Date Sonchl Martinelli 04 12 1997 Rev No Date Approved HVC Condenser Fan Motor K1 Compressor Contactor BS Defrost Probe HVE Evaporator Fan Motor H22 Internal Light BA Air Probe M1 Compresso...

Страница 52: ...roved Date Sonchl Martinelli 04 12 1997 Rev No Date Approved HVC Condenser Fan Motor K1 Compressor Contactor BS Defrost Probe HVE Evaporator Fan Motor H22 Internal Light BA Air Probe M1 Compressor EP...

Страница 53: ...l 45 98 141199 Fax 45 98 141703 Norway Hobart Foster Norge A S Tel 47 67 533878 Fax 47 67 536742 Sweden Hobart Foster Sverige AB Tel 46 0 8 584 50 920 Fax 46 0 8 584 50 929 PMI FEG Of ces Asia Paci c...