Foster FLY 2459930 Скачать руководство пользователя страница 5

5

Warning!

The remote fitted exhausting group (external motor) is built in class I plate, therefore 

it needs the earth connection.

The appliance was designed to exhaust odors and vapors in the best way. The ap-

pliance  is  to  be  installed  on  the  outside  wall  of  the  house  and  connected  to  the 

cooker-hood which is in the kitchen (fig. 1). 

Installation:

the mounting of the appliance is to be made by qualified technicians. Using the ap-

propriate drilling jig. 

(fig. 2) drill all the holes marked on it into the external wall, by paying attention not 

to damage water pipes or power lines. The holes on the wall are to be drilled with a 

8 mm. bit.

Insert, step by step, the following parts in the holes drilled:

- the corresponding plastic dowels supplied

- the two telescopic pipes in the hole of 200 mm.

- the plastic pipe of 40 mm. diameter.

Содержание FLY 2459930

Страница 1: ...AMAGE SUSTAINED DURING SHIPPING SHIPPING DAMAGE MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR BUILT IN HOODS Models covered by this instruction 2458 900 S...

Страница 2: ...ommencing in stallation All electrical wiring must be properly installed insulated and grounded and conform to all applicable codes and standards Make sure all existing duct work is clean of grease bu...

Страница 3: ...TABLE OF CONTENTS 3 Warnings 4 Useful warnings 4 Types of installation 5 Installation of the appliance 5 Connection of the pipes 6 Electrical connection of the hood 2459930 6 WARRANTY 7...

Страница 4: ...the pipe has not to be higher than 3 meters The material for the pipe has to be approved by an authorized company It is important to avoid changes in the diameter we recommend a diameter of 150mm Rea...

Страница 5: ...s in the kitchen fig 1 Installation the mounting of the appliance is to be made by qualified technicians Using the ap propriate drilling jig fig 2 drill all the holes marked on it into the external wa...

Страница 6: ...connect the two telescopic pipes fig C which are placed inside the wall with the cooker hood through the flexible pipes The fixing operations have to be carried out by using suitable metallic tools p...

Страница 7: ...directly during use and or maintenance and which may be subject to wear The formation of rust and stains on the steel due to the use of unsuitable cleaning agents Any functional defect indicated by t...

Страница 8: ...me by FOSTER with the desire of offering the best service available FOSTER is not liable for any damages direct or indirect caused to people objects and pets for failure to follow all the instructions...

Страница 9: ...s tension Tout le c blage lectrique doit tre correctement install isol de mise la terre conform ment aux codes et aux normes applicables Assurez vous que les conduits d vacuation sont propres et libre...

Страница 10: ...limentation lectrique 5 UTILISATION 6 INSTALLATION 7 PROC DURES D UTILISATION 9 Fonctions 9 ENTRETIENT 10 Remplacement des Ampoules 10 GARANTIE 12 10 Avertissements 11 avertissements utiles 11 Types d...

Страница 11: ...ble de la centrale ne doit pas tre coup ou branch avec autres c bles pour ne pas compromettre le correct fonctionnement et les conditions de s curit du produit Cela n est pas couvert par la garantie...

Страница 12: ...it de per age percer tous les trous indiqu s sur laquelle sur la paroi ext rieure en fai sant attention ne pas endommager les tuyauteries de l eau ou les lignes lectriques Les trous la paroi devront t...

Страница 13: ...pareil la paroi ext rieure les deux raccords t lescopiques qui se trouvent dans la paroi doivent tre connect s avec la hotte par les tuyaux flexibles Les tuyaux doivent tre fix s par des petites bande...

Страница 14: ...14...

Страница 15: ...et l usure Formation de rouille et taches sur l inox d l utilisation de d tergents pas adaptes Tout d faut fonctionnel indiqu par le client et pas v rifi pendant l examen de la part du technicien Dans...

Страница 16: ...st pas responsable pour tout ventuel d g t direct ou indirect caus personnes objets et animaux domestiques cause de l inobservance des instructions contenues dans la notice d utilisation et pour tout...

Отзывы: