Foster FLY 2459930 Скачать руководство пользователя страница 4

Warnings!

The air outlet of the appliance must not be connected to a flue which is used for 

exhausting

other fumes from appliances, such as a central heating, boilers etc..

For the external exhausting of the fumes, comply with the regulations in force.

Ventilate the room suitably according to the laws in force when the appliance is wor-

king together with gas, oil or coal burning appliances, at the same time.

The motor of the peripheral exhausting group is powered by the cooker-hood placed 

in the kitchen. 

Before connecting the cooker hood to the mains supply, make sure that the voltage 

indicated in the rating plate corresponds to the mains voltage in the home.

Before carrying out any sort of maintenance or cleaning operation, make sure that 

the appliance is disconnected from the electrical mains.

An appropriate maintenance ensures a good working and a good performance in the 

long run. 

Useful warnings:

- Use an air outlet pipe with a maximum length not higher than 5 meters.

- Limit the number of bends in the exhausting pipe as every bend reduces the per-

formance up to one linear meter. (If you use 2 90° bends, than the length of the pipe 

has not to be higher than 3 meters).

- The material for the pipe has to be approved by an authorized company.

-  It  is  important  to  avoid  changes  in  the  diameter  (we  recommend  a  diameter  of 

150mm).

- Read carefully the manual of instructions and installation of the unit.

- Sirius will not be responsible for problems of capacity and/ or noise level due to the 

missed respect of the warnings included in the manual of instructions. 

- SEM6 are equipped with a 200mm diameter hole for the exhausting pipe. If the 

unit that has to be connected to the remote fan is already equipped with a 200mm 

diameter hole, the nit is recommended to use a pipe with the same diameter in order 

to get good performances. Otherwise, if the unit is equipped with a 150mm diame-

ter hole, than it is recommended to use the joint (from 200mm to 150mm), already 

supplied with the unit.

The electric box cable should not be cut or joined together with other cables, since 

it could compromise the proper working and the safety conditions of the appliance. 

Furthermore, this will invalidate the manufacturer’s warranty coverage. 

Warnings!

The 2459930 suction centrals can be connected to any other products from the same 

manufacturer if they are equipped with the External Motor version. 

The manufacturer cannot be held responsible for damages caused by a different use.

4

Содержание FLY 2459930

Страница 1: ...AMAGE SUSTAINED DURING SHIPPING SHIPPING DAMAGE MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR BUILT IN HOODS Models covered by this instruction 2458 900 S...

Страница 2: ...ommencing in stallation All electrical wiring must be properly installed insulated and grounded and conform to all applicable codes and standards Make sure all existing duct work is clean of grease bu...

Страница 3: ...TABLE OF CONTENTS 3 Warnings 4 Useful warnings 4 Types of installation 5 Installation of the appliance 5 Connection of the pipes 6 Electrical connection of the hood 2459930 6 WARRANTY 7...

Страница 4: ...the pipe has not to be higher than 3 meters The material for the pipe has to be approved by an authorized company It is important to avoid changes in the diameter we recommend a diameter of 150mm Rea...

Страница 5: ...s in the kitchen fig 1 Installation the mounting of the appliance is to be made by qualified technicians Using the ap propriate drilling jig fig 2 drill all the holes marked on it into the external wa...

Страница 6: ...connect the two telescopic pipes fig C which are placed inside the wall with the cooker hood through the flexible pipes The fixing operations have to be carried out by using suitable metallic tools p...

Страница 7: ...directly during use and or maintenance and which may be subject to wear The formation of rust and stains on the steel due to the use of unsuitable cleaning agents Any functional defect indicated by t...

Страница 8: ...me by FOSTER with the desire of offering the best service available FOSTER is not liable for any damages direct or indirect caused to people objects and pets for failure to follow all the instructions...

Страница 9: ...s tension Tout le c blage lectrique doit tre correctement install isol de mise la terre conform ment aux codes et aux normes applicables Assurez vous que les conduits d vacuation sont propres et libre...

Страница 10: ...limentation lectrique 5 UTILISATION 6 INSTALLATION 7 PROC DURES D UTILISATION 9 Fonctions 9 ENTRETIENT 10 Remplacement des Ampoules 10 GARANTIE 12 10 Avertissements 11 avertissements utiles 11 Types d...

Страница 11: ...ble de la centrale ne doit pas tre coup ou branch avec autres c bles pour ne pas compromettre le correct fonctionnement et les conditions de s curit du produit Cela n est pas couvert par la garantie...

Страница 12: ...it de per age percer tous les trous indiqu s sur laquelle sur la paroi ext rieure en fai sant attention ne pas endommager les tuyauteries de l eau ou les lignes lectriques Les trous la paroi devront t...

Страница 13: ...pareil la paroi ext rieure les deux raccords t lescopiques qui se trouvent dans la paroi doivent tre connect s avec la hotte par les tuyaux flexibles Les tuyaux doivent tre fix s par des petites bande...

Страница 14: ...14...

Страница 15: ...et l usure Formation de rouille et taches sur l inox d l utilisation de d tergents pas adaptes Tout d faut fonctionnel indiqu par le client et pas v rifi pendant l examen de la part du technicien Dans...

Страница 16: ...st pas responsable pour tout ventuel d g t direct ou indirect caus personnes objets et animaux domestiques cause de l inobservance des instructions contenues dans la notice d utilisation et pour tout...

Отзывы: