background image

IV5016

-

E Issue J

 

Page 7 of 7

 

Foss AS 

 

P.O. Box 3614

 

N

-

3007 Drammen

 

Tel47 32 21 08 00

 

T47 32 21 08 08 

 

firmapost@foss

-

as.no

 

www.fossfibreoptics.com

 

The information in this document is believed to be reliable (including drawings and pictures). However, FOSS AS makes no warranties as to its 
accuracy or completeness and disclaims any liability in connection with its use. The document may contain inaccuracies and errors. In no case 
will FOSS AS be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the described 
products. Users of FOSS AS products should make their own evaluation to determine the suitability of each such product for the specific 
application. In no case will FOSS AS be liable for any errors, inaccuracies, omissions or lack of validity of information in this document. 

 

Any use or copying of this document for other purposes than it is intended is strictly forbidden. 

 

Prepare the cable(s) as shown in drawing 5.1.

 

 
 
 

Connectors for direct termination (e.g. FAST, UniCam, FuseConnect) are 
assembled according to the instructions from the supplier.

 

 

Then follow the instructions in chapter 4, figure 4.1 and onwards.

 

 
 
 
 
 
 
 
 

 
 

Prepare the cable(s) as shown in drawing 6.1.

 

Make sure every fibre is cleaned and that all grease is removed.

 

 
 

Connectors for direct termination (e.g. FAST, UniCam, FuseConnect) are 
assembled according to the instructions from the supplier.

 

 

Then follow the instructions in chapter 6A, figure 6.2 but do 

NOT

 install the 

splice holder.

 

 

The adapter plate may be lifted up and turned to give easier access to the 
adapters on the inside. See ch. 4.3.

 

 

Clean the adapters. Distribute the fibres on the guiding crosses according to 
the adapters they shall be mounted in.  Clean the connectors and insert them 
in the adapters.  

 

 

Close the fibre guides

 

(see picture 3.2.1).

 

7.2 Finished panel

 

7. Installing direct terminated cable

 

Direct termination may be used on several cable types. In the following cable with tight buffered fibre and loos tube cable are covered. 

 

7.1 Finished panel 

 

7A. Cable with tight buffered fibre

 

7B. Cable with loose tube

 

7.1 Finished panel

 

Содержание FP60

Страница 1: ...connectors may be prepolished and without glue or meant for glue and polishing in the field It may also be connectors intended for direct splicing to the fibre Glue free connectors may be e g FAST or UniCam Connectors for direct splicing to the fibre may be e g FuseConnect 2 Materials Tools Socket wrench 12 mm or 13 mm For use with FC or ST adapters Torx 25 screwdriver PZ2 screwdriver Heat gun Add...

Страница 2: ...2 This gives more space in front of the panel which may be beneficial e g if the distance to the doors in the front is very short When the panel is to be mounted in an ETSI metric rack the brackets are turned and assembled as shown in picture 3 3 After all installations make sure the fibre guides are closed see picture 3 1 1 19 assembly 3 1 2 Offset 19 assembly 3 1 3 ETSI assembly 3 2 1 Fibre guid...

Страница 3: ...The adapter plate may be lifted up and tilted to give easier access to the adapters on the inside See picture 4 3 Loosen the screws on the side and lift the plate up and forward as indicated by the arrow until it rest in the end of the track There it rests while the plate is tilted to the desired angle Tighten the screw to secure it in that position Clean the adapters Distribute the fibres on the ...

Страница 4: ...d turned to give easier access to the adapters on the inside See ch 4 3 Clean the adapters If the pigtails are more than 1 5 m long they should be cut to this length Clean the connectors and insert them in the adapters Attach splice protectors and splice the first 12 fibres put the fibres in the fibre guide crosses as shown in drawing 5 4 and place the splice protectors in the splice holders Fibre...

Страница 5: ...urned to give easier access to the adapters on the inside See ch 4 3 Clean the adapters If the pigtails are more than 1 5 m long they should be cut to this length Clean the connectors and insert them in the adapters Attach splice protectors and splice the first 12 fibres put the fibres in the fibre guide crosses as shown in drawing 5 4 and place the splice protectors in the splice holders Fibre nr...

Страница 6: ...ce holders in the two mid holes one for each holder as shown in drawing 6 5 They are fixed with rivets through one of the nut holes at the end of the holder shown as black dots Fasten the cable to the two foremost punched out mounts and to the lower hole in the back wall of the drawer using tie wraps Any excess cable must be handled outside of the panel The adapter plate may be lifted up and turne...

Страница 7: ...he cable s as shown in drawing 5 1 Connectors for direct termination e g FAST UniCam FuseConnect are assembled according to the instructions from the supplier Then follow the instructions in chapter 4 figure 4 1 and onwards Prepare the cable s as shown in drawing 6 1 Make sure every fibre is cleaned and that all grease is removed Connectors for direct termination e g FAST UniCam FuseConnect are as...

Отзывы: