Loosen the snap
-
latches and pull out the drawer.
Insert the adapters. SC adapters are inserted with the guide tracks to the
right, FC adapters with the guide tracks to the left. LC adapters are inserted
with the lock to the right.
Fasten the cable to the two foremost punched out mounts in the drawer
using tie
-
wraps. If a second cable is used this is fastened to the backmost
mount and to the two upper holes in the rear wall as shown in picture 4.2.
Any excess cable must be handled outside of the panel.
The adapter plate may be lifted up and tilted to give easier access to the
adapters on the inside. See picture 4.3.
Loosen the screws on the side and lift the plate up and forward (as indicated
by the arrow) until it rest in the end of the track. There it rests while the plate
is tilted to the desired angle. Tighten the screw to secure it in that position.
Clean the adapters. Distribute the fibres on the guiding crosses according to
the adapters they shall be mounted in. Clean the connectors and insert them
in the adapters.
Close the fibre guides
(see picture 3.2.1).
4.1 Interior of the panel
4.2 Fastening the cables
4. Installing pre
-
terminated cable with tight buffered fibre
4.4 Finished panel.
4.3 The adapter plate may be tilted