background image

MANUAL IV5016

-

E Issue J Page 1 of 7

 

fossfibreoptics.com

 

1. General

 

This manual describes installation of pre

-

terminated cable, termination of cable using splicing and direct termination* of cable in panel 

FP60

 

PRO or FP65 PRO. Some parts of the shown installations may already be finished before delivery. If installing less fibres and/or other 

adapter types than shown, the manual is followed to the extent possible. When terminating less fibres than the adapter plate can hold, the 
rest of the holes are fitted with blind plugs.

 

 

All installation is described with the cable from the left side. If the cable should be from the right, the installation has to be mirrored 
accordingly. 

 

 

It is recommended to read the whole manual once before starting the installation.

 

 

Colour codes for cables delivered by Foss may be found under the icons to the right.

 

 

 

Direct terminated cable means that the cable is prepared and the connectors assembled in the field. The connectors may be prepolished and 
without glue or meant for glue and polishing in the field. It may also be connectors intended for direct splicing to the fibre. Glue

-

free 

connectors may be e.g. FAST or UniCam. Connectors for direct splicing to the fibre may be e.g. FuseConnect.

 

 

 
 
 

2. Materials

 

Tools:

 

 

 

Socket wrench 12 mm or 13 mm

 

 

For use with FC or ST adapters

 

 

 

Torx 25 screwdriver 

   

 

 

PZ2 screwdriver 

 

 

 

 

Heat gun

 

 

 

Additional equipment:

 

Depending on the application the following may be necessary:

 

 

PS

-

3A

-

X

 

 

Heat shrink tube, 60 mm, 100 pkn

 

 

For splicing

 

PS

-

3A

-

X/45

 

 

Heat shrink tube, 45 mm, 100 pkn

 

 

Alternative to 60 mm

 

4415

   

 

Cleaning kit, cables, grease

 

 

 

For cables with loose tube

 

 

Content

 

1.

 

General

 ...................................................................................................... 

1

 

2.

 

Materials

 .................................................................................................... 

1

 

3.1

 

Alternative bracket assembly 

.................................................................... 

2

 

3.2

 

Closing the fibre guides

.............................................................................. 

2

 

4.

 

Installing pre

-

terminated cable with tight buffered fibre

 .......................... 

3

 

5.

 

Splicing cable with tight buffered fibre

 ...................................................... 

 

6.

 

Splicing cable with loose tube

 

 

A.

 

Fibre tubes, up to 48 fibres

 .................................................................. 

5

 

 

B.

 

Fibre tubes, over 48 fibres (High Density)

 ........................................... 

6

 

 

C.

 

Fibre tubes, in corrugated tubes

 ......................................................... 

6

 

7.

 

Installing direct terminated cable

 

 

A.

 

Cable with tight buffered fibre

 ............................................................ 

7

 

 

B.

 

Cable with loose tube

 .......................................................................... 

7

 

Panel installation FP60/65

 

Colour codes

 

Содержание FP60

Страница 1: ...connectors may be prepolished and without glue or meant for glue and polishing in the field It may also be connectors intended for direct splicing to the fibre Glue free connectors may be e g FAST or UniCam Connectors for direct splicing to the fibre may be e g FuseConnect 2 Materials Tools Socket wrench 12 mm or 13 mm For use with FC or ST adapters Torx 25 screwdriver PZ2 screwdriver Heat gun Add...

Страница 2: ...2 This gives more space in front of the panel which may be beneficial e g if the distance to the doors in the front is very short When the panel is to be mounted in an ETSI metric rack the brackets are turned and assembled as shown in picture 3 3 After all installations make sure the fibre guides are closed see picture 3 1 1 19 assembly 3 1 2 Offset 19 assembly 3 1 3 ETSI assembly 3 2 1 Fibre guid...

Страница 3: ...The adapter plate may be lifted up and tilted to give easier access to the adapters on the inside See picture 4 3 Loosen the screws on the side and lift the plate up and forward as indicated by the arrow until it rest in the end of the track There it rests while the plate is tilted to the desired angle Tighten the screw to secure it in that position Clean the adapters Distribute the fibres on the ...

Страница 4: ...d turned to give easier access to the adapters on the inside See ch 4 3 Clean the adapters If the pigtails are more than 1 5 m long they should be cut to this length Clean the connectors and insert them in the adapters Attach splice protectors and splice the first 12 fibres put the fibres in the fibre guide crosses as shown in drawing 5 4 and place the splice protectors in the splice holders Fibre...

Страница 5: ...urned to give easier access to the adapters on the inside See ch 4 3 Clean the adapters If the pigtails are more than 1 5 m long they should be cut to this length Clean the connectors and insert them in the adapters Attach splice protectors and splice the first 12 fibres put the fibres in the fibre guide crosses as shown in drawing 5 4 and place the splice protectors in the splice holders Fibre nr...

Страница 6: ...ce holders in the two mid holes one for each holder as shown in drawing 6 5 They are fixed with rivets through one of the nut holes at the end of the holder shown as black dots Fasten the cable to the two foremost punched out mounts and to the lower hole in the back wall of the drawer using tie wraps Any excess cable must be handled outside of the panel The adapter plate may be lifted up and turne...

Страница 7: ...he cable s as shown in drawing 5 1 Connectors for direct termination e g FAST UniCam FuseConnect are assembled according to the instructions from the supplier Then follow the instructions in chapter 4 figure 4 1 and onwards Prepare the cable s as shown in drawing 6 1 Make sure every fibre is cleaned and that all grease is removed Connectors for direct termination e g FAST UniCam FuseConnect are as...

Отзывы: